Combination of forced diuresis with additional late imaging in 68Ga-PSMA-11 PET/CT: effects on lesion visibility and radiotracer uptake

I Alberts, J Niklas-Hünermund… - Journal of Nuclear …, 2021 - Soc Nuclear Med
Renal excretion of some prostate-specific membrane antigen (PSMA) ligands and
consequently increased bladder activity can obscure locally relapsing prostate cancer …

[HTML][HTML] Combined forced diuresis and late acquisition on [68Ga]Ga-PSMA-11 PET/CT for biochemical recurrent prostate cancer: a clinical practice-oriented study

M Bauckneht, A Miceli, A Signori, D Albano… - European …, 2023 - Springer
Objectives Increased detection of prostate cancer (PCa) recurrences using [68Ga] Ga-PSMA-
11 PET/CT has been reported by adding forced diuresis or late-phase imaging to the …

Early dynamic imaging in 68Ga- PSMA-11 PET/CT allows discrimination of urinary bladder activity and prostate cancer lesions

C Uprimny, AS Kroiss, C Decristoforo, J Fritz… - European journal of …, 2017 - Springer
Abstract Purpose PET/CT with 68 Ga-labelled prostate-specific membrane antigen (PSMA)-
ligands has been proven to establish a promising imaging modality in the work-up of …

68Ga-PSMA I&T PET/CT for assessment of prostate cancer: evaluation of image quality after forced diuresis and delayed imaging

T Derlin, D Weiberg, C von Klot, HJ Wester… - European …, 2016 - Springer
Objective Urinary radiotracer excretion of 68 Ga-Labelled prostate-specific membrane
antigen (PSMA) ligands may complicate the assessment of the prostate region and …

The clinical impact of additional late PET/CT imaging with 68Ga-PSMA-11 (HBED-CC) in the diagnosis of prostate cancer

A Afshar-Oromieh, LP Sattler, W Mier… - Journal of nuclear …, 2017 - Soc Nuclear Med
Although PET/CT with 68Ga-PSMA-11 in the diagnosis of prostate cancer (PCa) is routinely
performed at 1 h after injection, later scans may be beneficial because most lesions present …

Impact of forced diuresis with furosemide and hydration on the halo artefact and intensity of tracer accumulation in the urinary bladder and kidneys on [68Ga]Ga …

C Uprimny, S Bayerschmidt, AS Kroiss, J Fritz… - European Journal of …, 2021 - Springer
Purpose to assess the influence of intravenous hydration and forced diuresis with
furosemide in two different dosages (20 vs 40 mg) on the intensity of tracer accumulation in …

[HTML][HTML] 68Ga-PSMA-11 PET/CT in prostate cancer local recurrence: impact of early images and parametric analysis

C Sachpekidis, L Pan, BA Hadaschik… - American journal of …, 2018 - ncbi.nlm.nih.gov
Abstract 68 Ga-PSMA-11 PET/CT performed 60 min post tracer injection (pi) can
underestimate prostate cancer (PC) local recurrence, due to high 68 Ga-PSMA-11 urinary …

[HTML][HTML] 68Ga PSMA-11 PET with CT urography protocol in the initial staging and biochemical relapse of prostate cancer

A Iravani, MS Hofman, T Mulcahy, S Williams… - Cancer Imaging, 2017 - Springer
Background 68 Ga-labelled prostate specific membrane antigen (PSMA) ligand PET/CT is a
promising modality in primary staging (PS) and biochemical relapse (BCR) of prostate …

68Ga-PSMA-11 PET/CT in patients with recurrent prostate cancer—a modified protocol compared with the common protocol

F Haupt, L Dijkstra, I Alberts, C Sachpekidis… - European journal of …, 2020 - Springer
Abstract Purpose 68 Ga-PSMA-11 PET/CT is commonly performed at 1 h post injection (pi).
However, various publications have demonstrated that most prostate cancer (PC) lesions …

[HTML][HTML] Effects of furosemide and tracer selection on urinary activity and peri-bladder artefacts in PSMA PET/CT: a single-centre retrospective study

ML Donswijk, M Wondergem, L de Wit-van der Veen… - EJNMMI research, 2022 - Springer
Background High urinary activity in urinary bladder and ureters may hamper interpretation of
prostate cancer and regional nodal metastases in prostate-specific membrane antigen …