Evaluation of automated VOI definition freeware tools for PET data analysis of striatal dopaminergic system

H Kuwabara, PL Bazin, A Nandi, W Chamroonrat… - 2011 - Soc Nuclear Med
2045 Objectives Recent automated volume of interest (VOI) defining tools are expect to
facilitate PET data analysis. Four freeware tools, namely TOADS (TS; Bazan et al., 2007) …

Evaluation of a supervised, interpolation method for volumes of interest definition for PET neuroimaging studies

H Kuwabara, H Jung, A Nandi, A Kumar, D Wong - 2012 - Soc Nuclear Med
2296 Objectives Software packages of automated method for volumes of interest (VOIs) are
widely used. However, we reported (JNM 52: 2045) that tested automated methods …

Evaluation of partial volume correction and segmentation methods for dynamic dopaminergic PET study based on simulated PET

Y Rong, O Winz, I Vernaleken, F Mottaghy - 2011 - Soc Nuclear Med
1978 Objectives Partial volume effect is a considerable issue in PET striatum study. In this
work we evaluate several sophisticated partial volume correction (PVC) algorithms …

Evaluation of BTXBrain-Dopamine, AI-powered automated quantification software for dopamine transporter PET

SK Kang, D Kim, SA Shin, H Choi, JS Lee - 2022 - Soc Nuclear Med
2502 Introduction: Dopamine transporter (DAT) imaging is widely performed to evaluate the
function of presynaptic dopaminergic neurons and is particularly useful in the differential …

Metrics to track dopamine release magnitude using PET: Comparison of Residual Space Detection and linear parametric neurotransmitter PET

JU Hanania, CWJ Bevington… - 2023 IEEE Nuclear …, 2023 - ieeexplore.ieee.org
Residual Space Detection (RSD) has been previously shown to improve upon traditional
methods for detecting low-magnitude dopamine (DA) release in the human brain by use of …

Validation of Simple Quantification Methods for 18F-FP-CIT PET Using Automatic Delineation of Volumes of Interest Based on Statistical Probabilistic Anatomical …

Y Kim, HJ Im, JC Paeng, JS Lee, JS Eo, DH Kim… - Nuclear medicine and …, 2012 - Springer
Abstract Purpose 18 F-FP-CIT positron emission tomography (PET) is an effective imaging
for dopamine transporters. In usual clinical practice, 18 F-FP-CIT PET is analyzed visually or …

A simple algorithm for subregional striatal uptake analysis with partial volume correction in dopaminergic PET imaging

KH Lue, HH Lin, CHK Kao, HJ Hsieh, SH Liu… - Annals of nuclear …, 2014 - Springer
Objective In positron emission tomography (PET) of the dopaminergic system, quantitative
measurements of nigrostriatal dopamine function are useful for differential diagnosis. A …

Embedding Partial Volume Correction in Atlas-Based Image Analysis for Substriatal Uptake in Dopaminergic PET Imaging

KH Lue, HH Lin, YH Chen, SH Liu, KS Chuang - 2019 - Soc Nuclear Med
3001 Objectives: PET is an invaluable molecular imaging tool that visualizes the
dopaminergic system. Quantitative measurements of nigrostriatal dopamine functions are …

External evaluation of an automated quantification software for dopamine transporter PET without MRI

SK Kang, D Kim, SA Shin, H Choi, YK Kim, JS Lee - 2023 - Soc Nuclear Med
P572 Introduction: One of the neurodegenerative diseases, Parkinson9s disease, is often
not identified until they have advanced considerably. One commonly used method for early …

Supervised clustering for obtaining a reference tissue region in dynamic 11C-PE2I PET data

M Jonasson, L Appel, T Danfors, J Sörensen… - 2013 - Soc Nuclear Med
2131 Objectives The PET ligand 11 C-PE2I is highly selective for the dopamine transporter
(DAT) and parametric images based on a dynamic 11 C-PE2I scan, showing DAT …