[PDF][PDF] Quantitative mapping of regional cerebral blood flow using iodine-123-IMP and SPECT

H Iida, H Itoh, M Nakazawa, J Hatazawa… - Journal of Nuclear …, 1994 - Soc Nuclear Med
A method was developed to calculate functionalimages of re gional cerebral blood flow
(rCBF) from a single scan using SPECT followingintravenous 1@ IN-isopropyt-p …

A Multicenter Validation of Regional Cerebral Blood Flow Quantitation Using [123I]Iodoamphetamine and Single Photon Emission Computed Tomography

H Iida, T Akutsu, K Endo, H Fukuda… - Journal of Cerebral …, 1996 - journals.sagepub.com
Recently, two methods have been proposed for regional cerebral blood flow (rCBF)
quantitation using [123I] iodoamphetamine (IMP) and single-photon emission computed …

Quantification of regional cerebral blood flow with IMP-SPECT. Reproducibility and clinical relevance of flow values.

I Podreka, C Baumgartner, E Suess, C Müller, T Brücke… - Stroke, 1989 - Am Heart Assoc
Single-photon emission computed tomography with N-isopropyl [123I]-p-iodoamphetamine
(IMP-SPECT) was performed in 14 normal volunteers (seven men and seven women aged …

Regional cerebral blood flow measurement with iodine-123-IMP autoradiography: normal values, reproducibility and sensitivity to hypoperfusion

J Hatazawa, H Iida, E Shimosegawa… - The Journal of Nuclear …, 1997 - search.proquest.com
We recently proposed a simplified technique for measuring regional cerebral blood flow
(rCBF) using the [123I] N-isopropyl-p-iodoamphetamine (IMP) autoradiographic (ARG) …

[PDF][PDF] Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT

H Iida, Y Narita, H Kado, A Kashikura… - Journal of Nuclear …, 1998 - Soc Nuclear Med
IJLmaps in the lower slices due to the airways and in the higher slices due to increased skull
attenuation. However, differences were< 5% in all cerebral tissue regions, thus assumption …

Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 …

K Inoue, R Goto, S Kinomura, Y Taki, K Okada… - Annals of nuclear …, 2006 - Springer
Objectives Three accumulative tracers, iodine-123-labeled N-isopropyl-p-iodoamphetamine
(I-123-IMP), technetium-99m-labeled hexamethylpropyleneamineoxime (Tc-99m-HMPAO) …

Quantitative Measurements of Cerebral Blood Flow Using SPECT and [99mTc]-d,l-HM-PAO Compared to Xenon-133

AR Andersen, HH Friberg, JF Schmidt… - Journal of Cerebral …, 1988 - journals.sagepub.com
The uptake and retention in a 2 cm thick brain section was recorded serially by SPECT after
iv injection of [99mTc]–d, l-HM-PAO (HM-PAO). In 16 patients, the fraction of the …

Absolute quantification of cerebral blood flow in normal volunteers: correlation between Xe‐133 SPECT and dynamic susceptibility contrast MRI

L Knutsson, S Börjesson, EM Larsson… - Journal of Magnetic …, 2007 - Wiley Online Library
Purpose To compare absolute cerebral blood flow (CBF) estimates obtained by dynamic
susceptibility contrast MRI (DSC‐MRI) and Xe‐133 SPECT. Materials and Methods CBF was …

Quantification of regional cerebral blood flow (rCBF) using 99Tcm-HMPAO and SPECT: choice of the reference region

GMS Syed, S Eagger, BK Toone, R Levy… - Nuclear medicine …, 1992 - journals.lww.com
The effects of the choice of the reference region in determining the relative regional cerebral
blood flow (rCBF) using 99 Tc m-hexamethylpropylene amine oxime (HMPAO) single …

A new graphic plot analysis for cerebral blood flow and partition coefficient with iodine-123-iodoamphetamine and dynamic SPECT validation studies using oxygen-15 …

T Yokoi, H Iida, H Itoh, I Kanno - Journal of Nuclear Medicine …, 1993 - europepmc.org
To estimate regional cerebral blood flow (rCBF) and brain-blood partition coefficient