[PDF][PDF] Myocardial tissue fraction—correction for partial volume effects and measure of tissue viability
H Iida, CG Rhodes, R de Silva… - Journal of Nuclear …, 1991 - Soc Nuclear Med
In the present study we have compared the implemen tation of partial volume correction by
the tissue fraction technique with an alternative independent method that requires the …
the tissue fraction technique with an alternative independent method that requires the …
Nongeometric determination of left ventricular volumes from equilibrium blood pool scans
GJ Dehmer, SE Lewis, LD Hillis, D Twieg… - The American journal of …, 1980 - Elsevier
This study assesses the utility of a scintigraphic, nongeometric technique for the
determination of left ventricular volumes. Accordingly, gated blood pool scintigraphy and …
determination of left ventricular volumes. Accordingly, gated blood pool scintigraphy and …
Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume …
H Iida, I Kanno, A Takahashi, S Miura, M Murakami… - Circulation, 1988 - Am Heart Assoc
An in vivo technique was developed for measuring the absolute myocardial blood flow with
H215O and dynamic positron-emission tomography. This technique was based on a new …
H215O and dynamic positron-emission tomography. This technique was based on a new …
Modelling the integration of myocardial regional perfusion and function
ML Goris, C Thompson, LJ Malone… - Nuclear medicine …, 1994 - journals.lww.com
The purpose of the study is to describe a method for the investigation of myocardial kinetics
(wall motion or wall thickening) to define myocardial perfusion characteristics further. The …
(wall motion or wall thickening) to define myocardial perfusion characteristics further. The …
Correction of partial volume effects in myocardial SPECT
BF Hutton, A Osiecki - Journal of Nuclear Cardiology, 1998 - Elsevier
Background. Marked partial volume effects occur in myocardial single photon emission
computed tomographic (SPECT) studies because of limited resolution in imaging the …
computed tomographic (SPECT) studies because of limited resolution in imaging the …
Radionuclide measurement of left ventricular volume: comparison of geometric and counts-based methods.
BM Massie, BL Kramer, EW Gertz, SG Henderson - Circulation, 1982 - Am Heart Assoc
Radionuclide measurements of left ventricular volume were determined in 20 patients by
geometric and nongeometric, counts-based techniques using data from first-pass and …
geometric and nongeometric, counts-based techniques using data from first-pass and …
Measurement of absolute left ventricular volume from gated blood pool studies.
JM Links, LC Becker, JG Shindledecker, P Guzman… - Circulation, 1982 - Am Heart Assoc
SUMMARY A new method for obtaining absolute left ventricular volume from gated blood
pool studies was evaluated in a torso phantom and in 35 patients who also underwent …
pool studies was evaluated in a torso phantom and in 35 patients who also underwent …
[PDF][PDF] Four radionuclide methods for left ventricular volume determination: comparison of a manual and an automated technique
WC Levy, MD Cerqueira, DT Matsuoka… - Journal of Nuclear …, 1992 - Soc Nuclear Med
and an Automated Technique Page 1 Links et al. (1) and Starling et al. (2) introduced atten
uation-corrected count-based distance methods to deter mine left ventricular volumes using …
uation-corrected count-based distance methods to deter mine left ventricular volumes using …
Assessment of myocardial viability
MI Travin, SR Bergmann - Seminars in nuclear medicine, 2005 - Elsevier
The prevalence of left ventricular (LV) dysfunction and resultant congestive heart failure is
increasing. Patients with this condition are at high risk for cardiac death and usually have …
increasing. Patients with this condition are at high risk for cardiac death and usually have …
Radionuclide measurement of left ventricular volume.
IP Clements, ML Brown, HC Smith - Mayo Clinic Proceedings, 1981 - europepmc.org
Count rates observed at end-diastole and end-systole in the region of the left ventricle on
gated radionuclide angiograms were correlated with corresponding estimates by biplane …
gated radionuclide angiograms were correlated with corresponding estimates by biplane …
Related searches
- tissue fraction partial volume effects
- volume effects measure of tissue viability
- myocardial spect partial volume effects
- partial volume effect positron emission
- partial volume effect blood flow
- partial volume effect quantification in relation
- tissue viability partial volume effects
- partial volume effect strategy for quantification