An improved method for automatic segmentation of the left ventricle in myocardial perfusion SPECT
H Soneson, JFA Ubachs, M Ugander… - Journal of Nuclear …, 2009 - Soc Nuclear Med
This study describes and validates a new method for automatic segmentation of left
ventricular mass (LVM) in myocardial perfusion SPECT (MPS) images. This is important for …
ventricular mass (LVM) in myocardial perfusion SPECT (MPS) images. This is important for …
Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac …
H Soneson, F Hedeer, C Arévalo, M Carlsson… - Journal of Nuclear …, 2011 - Elsevier
Background By gating image acquisition in myocardial perfusion SPECT (MPS) to ECG, left
ventricular (LV) volumes and function can be determined. Several previous studies have …
ventricular (LV) volumes and function can be determined. Several previous studies have …
A learning-based automatic segmentation and quantification method on left ventricle in gated myocardial perfusion SPECT imaging: A feasibility study
Background The performance of left ventricular (LV) functional assessment using gated
myocardial perfusion SPECT (MPS) relies on the accuracy of segmentation. Current …
myocardial perfusion SPECT (MPS) relies on the accuracy of segmentation. Current …
Automated quality control for segmentation of myocardial perfusion SPECT
Y Xu, P Kavanagh, M Fish, J Gerlach… - Journal of Nuclear …, 2009 - Soc Nuclear Med
Left ventricular (LV) segmentation, including accurate assignment of LV contours, is
essential for the quantitative assessment of myocardial perfusion SPECT (MPS). Two major …
essential for the quantitative assessment of myocardial perfusion SPECT (MPS). Two major …
Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to …
L Stegger, CSA Lipke, P Kies, B Nowak… - European journal of …, 2007 - Springer
Purpose The segmentation algorithm ESM based on an elastic surface model was validated
for the assessment of left ventricular volumes and ejection fraction from ECG-gated …
for the assessment of left ventricular volumes and ejection fraction from ECG-gated …
Model-based quantification of myocardial perfusion images from SPECT.
A system for quantitative analysis of myocardial perfusion tomograms is proposed. The
system starts with an automated delineation of the total left ventricle, including possible …
system starts with an automated delineation of the total left ventricle, including possible …
“Same-Patient Processing” for multiple cardiac SPECT studies. 1. Improving LV segmentation accuracy
G Germano, PB Kavanagh, MB Fish… - Journal of nuclear …, 2016 - Springer
Objectives This paper describes a novel approach (same-patient processing, or SPP) aimed
at improving left ventricular segmentation accuracy in patients with multiple SPECT studies …
at improving left ventricular segmentation accuracy in patients with multiple SPECT studies …
An automatic method for quantification of myocardium at risk from myocardial perfusion SPECT in patients with acute coronary occlusion
H Soneson, H Engblom, E Hedström, F Bouvier… - Journal of nuclear …, 2010 - Springer
Background In order to determine myocardial salvage, accurate quantification of
myocardium at risk (MaR) is necessary. We present a validated novel automatic …
myocardium at risk (MaR) is necessary. We present a validated novel automatic …
[HTML][HTML] Automatic segmentation of myocardium at risk from contrast enhanced SSFP CMR: validation against expert readers and SPECT
Background Efficacy of reperfusion therapy can be assessed as myocardial salvage index
(MSI) by determining the size of myocardium at risk (MaR) and myocardial infarction …
(MSI) by determining the size of myocardium at risk (MaR) and myocardial infarction …
Experimental validation of a new quantitative method for the analysis of infarct size by cardiac perfusion tomography (SPECT)
L Mortelmans, J Nuyts, J Vanhaecke… - … International Journal of …, 1993 - Springer
Using global constraints and dynamic programming, a new model-based segmentation
algorithm was developed to determine myocardial borders and basal plane. The segmented …
algorithm was developed to determine myocardial borders and basal plane. The segmented …
Related searches
- left ventricle perfusion spect
- left ventricle automatic segmentation
- perfusion spect automatic segmentation
- perfusion spect quantification of myocardium
- myocardium at risk automatic segmentation
- expert readers automatic segmentation
- perfusion spect quality control
- perfusion images ventricular segmentation
- left ventricle spect imaging
- perfusion spect myocardium at risk