An improved method for automatic segmentation of the left ventricle in myocardial perfusion SPECT

H Soneson, JFA Ubachs, M Ugander… - Journal of Nuclear …, 2009 - Soc Nuclear Med
This study describes and validates a new method for automatic segmentation of left
ventricular mass (LVM) in myocardial perfusion SPECT (MPS) images. This is important for …

Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac …

H Soneson, F Hedeer, C Arévalo, M Carlsson… - Journal of Nuclear …, 2011 - Elsevier
Background By gating image acquisition in myocardial perfusion SPECT (MPS) to ECG, left
ventricular (LV) volumes and function can be determined. Several previous studies have …

A learning-based automatic segmentation and quantification method on left ventricle in gated myocardial perfusion SPECT imaging: A feasibility study

T Wang, Y Lei, H Tang, Z He, R Castillo… - Journal of Nuclear …, 2020 - Springer
Background The performance of left ventricular (LV) functional assessment using gated
myocardial perfusion SPECT (MPS) relies on the accuracy of segmentation. Current …

Automated quality control for segmentation of myocardial perfusion SPECT

Y Xu, P Kavanagh, M Fish, J Gerlach… - Journal of Nuclear …, 2009 - Soc Nuclear Med
Left ventricular (LV) segmentation, including accurate assignment of LV contours, is
essential for the quantitative assessment of myocardial perfusion SPECT (MPS). Two major …

Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to …

L Stegger, CSA Lipke, P Kies, B Nowak… - European journal of …, 2007 - Springer
Purpose The segmentation algorithm ESM based on an elastic surface model was validated
for the assessment of left ventricular volumes and ejection fraction from ECG-gated …

Model-based quantification of myocardial perfusion images from SPECT.

J Nuyts, L Mortelmans, P Suetens… - Journal of Nuclear …, 1989 - europepmc.org
A system for quantitative analysis of myocardial perfusion tomograms is proposed. The
system starts with an automated delineation of the total left ventricle, including possible …

“Same-Patient Processing” for multiple cardiac SPECT studies. 1. Improving LV segmentation accuracy

G Germano, PB Kavanagh, MB Fish… - Journal of nuclear …, 2016 - Springer
Objectives This paper describes a novel approach (same-patient processing, or SPP) aimed
at improving left ventricular segmentation accuracy in patients with multiple SPECT studies …

An automatic method for quantification of myocardium at risk from myocardial perfusion SPECT in patients with acute coronary occlusion

H Soneson, H Engblom, E Hedström, F Bouvier… - Journal of nuclear …, 2010 - Springer
Background In order to determine myocardial salvage, accurate quantification of
myocardium at risk (MaR) is necessary. We present a validated novel automatic …

[HTML][HTML] Automatic segmentation of myocardium at risk from contrast enhanced SSFP CMR: validation against expert readers and SPECT

J Tufvesson, M Carlsson, AH Aletras, H Engblom… - BMC medical …, 2016 - Springer
Background Efficacy of reperfusion therapy can be assessed as myocardial salvage index
(MSI) by determining the size of myocardium at risk (MaR) and myocardial infarction …

Experimental validation of a new quantitative method for the analysis of infarct size by cardiac perfusion tomography (SPECT)

L Mortelmans, J Nuyts, J Vanhaecke… - … International Journal of …, 1993 - Springer
Using global constraints and dynamic programming, a new model-based segmentation