Standardization and quantification of radionuclide solid gastric-emptying studies

HA Ziessman, FH Fahey, FB Atkins… - Journal of Nuclear …, 2004 - Soc Nuclear Med
The purposes of this investigation were to standardize and validate a simple quantitative
method for performing radionuclide solid gastric emptying that can be used for any dual …

Comparison of gastric emptying scintigraphy based on the geometric mean of the gastric proportion of the abdominal radioactivity or on the geometric mean of the …

PY Salaun, S Querellou, JM Nguyen… - Nuclear medicine …, 2006 - journals.lww.com
Purpose Using gastric emptying scintigraphy the gastric retention rate is commonly
calculated within a gastric region of interest (intragastric method). This technique may have …

Technical considerations in radionuclide gastric emptying studies

PE Christian, FL Datz, JG Moore - Journal of nuclear medicine …, 1987 - Soc Nuclear Med
This is the final article in a four-part Continuing Education series on quantitative imaging
techniques. After studying this article, the reader should be able to: 1) identify proper use of …

[PDF][PDF] Gastric emptying rate assessment based on the proportion of intra-abdominal radioactivity in the stomach

HC Lien, CS Chang, GH Chen, CH Kao… - Journal of Nuclear …, 1999 - Soc Nuclear Med
Using scintigraphic techniques, the rate of gastric emptying is calculated by quantifying the
absolute radioactivity within a gastric region of interest (¡ ntragastricmethod) with the time …

Consensus report on gastric emptying: what's needed to prevent tarnishing a gold standard?

A Maurer - Journal of Nuclear Medicine, 2008 - Soc Nuclear Med
This editorial is to call to the attention of the nuclear medicine community a new consensus
report that establishes a standardized methodology for performing gastric-emptying studies …

Experience with a simplified, standardized 4-hour gastric-emptying protocol

HA Ziessman, DV Bonta, S Goetze… - Journal of Nuclear …, 2007 - Soc Nuclear Med
Gastric-emptying studies have no accepted standard methodology or reference values. A
simplified standardized protocol with a large reference database has been proposed, with …

[PDF][PDF] Comparison of left anterior oblique, anterior and geometric mean methods for determining gastric emptying times

PV Ford, RL Kennedy, JM Vogel - Journal of Nuclear Medicine, 1992 - Soc Nuclear Med
METHOD We studied 42 consecutive adult patients with normal gastric anatomy using our
standard protocol with the addition ofa LAO view. Our standard solid test meal consisted of …

Multicenter validation of a shortened gastric-emptying protocol

M Pelletier-Galarneau, OO Sogbein… - Journal of Nuclear …, 2015 - Soc Nuclear Med
Gastric emptying scintigraphy is considered to be the gold standard for detection of
gastroparesis and other disorders of gastric motility; Society of Nuclear Medicine and …

[PDF][PDF] Evaluation of an inexpensive screening scintigraphic test of gastric emptying

GM Thomforde, M Camilleri, SF Phillips… - Journal of Nuclear …, 1995 - Soc Nuclear Med
Our goal was to study the accuracy of a limited assessment relative to the traditional and
obtain a more detailed approach to measure gastric emptying. Methods: We prospectively …

Consensus recommendations for gastric emptying scintigraphy: a joint report of the American Neurogastroenterology and Motility Society and the Society of Nuclear …

TL Abell, M Camilleri, K Donohoe… - Journal of nuclear …, 2008 - Soc Nuclear Med
This consensus statement from the members of the American Neurogastroenterology and
Motility Society and the Society of Nuclear Medicine recommends a standardized method for …