Advantages of short-lived positron-emitting radioisotopes for intracoronary radiation therapy with liquid-filled balloons to prevent restenosis

HP Stoll, GD Hutchins, WL Winkle… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Balloon catheters filled with liquid radioisotopes provide excellent dose homogeneity for
intracoronary radiation therapy but are associated with risk for rupture or leakage. We …

Intravascular radiation therapy with radioactive liquid-filled balloons for inhibition of restenosis after angioplasty: A new opportunity for nuclear medicine?

FFR Knapp, RH Spencer, J Kropp - Journal of Nuclear Medicine, 2001 - Soc Nuclear Med
Over the past decade, the introduction of coronary stents brought a quantum improvement in
postangiographic treatment of diseased coronary arteries by providing a scaffolding that …

Evaluation of three rhenium-188 candidates for intravascular radiation therapy with liquid-filled balloons to prevent restenosis

WY Lin, SC Tsai, BT Hsieh, TW Lee, G Ting… - Journal of Nuclear …, 2000 - Springer
Background Intravascular brachytherapy is an effective method for inhibiting coronary
restenosis after percutaneous transluminal coronary angioplasty. A new concept for …

Anti-restenotic effect of copper-62 liquid-filled balloon in porcine coronary arteries: novel use of a short half-life positron emitter

RC Chan, JL Lacy, B Bhargava, SD Collins… - International Journal of …, 2000 - Elsevier
Purpose: To determine the efficacy of the use of copper-62, a positron emitter with a half-life
of 9.7 minutes, as an intracoronary brachytherapy (IRBT) source in the prevention of …

Intravascular irradiation using Re-186 liquid-filled balloon catheters: correlation between experimental and theoretical studies

AJ McGoron, WM Kassing, SR Thomas… - Cardiovascular …, 1999 - Elsevier
Purpose. Optimization of intravascular radiation to reduce stenosis following coronary
angioplasty requires the ability to predict the patterns of radiation dose distribution. This …

[PDF][PDF] Radiant liquid isotope intravascular radiation therapy system

N Eigler, J Whiting, RAJ Makkar, H Honda, FF Knapp… - 2000 - osti.gov
Device RADIA-NT'” is manufactured by United States Surgical Corporation, Vascular
Therapies Division,(formerly Progressive Angioplasty Systems). The system comprises a …

Rhenium-188-Labeled DTPA: a new radiopharmaceutical for intravascular radiation therapy

BT Hsieh, JF Hsieh, SC Tsai, WY Lin, HT Huang… - Nuclear medicine and …, 1999 - Elsevier
Balloon angioplasty is a standard treatment for artherosclerotic coronary artery disease.
However, its clinical value is reduced by a high restenosis rate. A new concept in preventing …

Radioactive beta-emitting solution-filled balloon treatment prevents porcine coronary restenosis

J Weinberger, KN Giedd, AD Simon, C Marboe… - Cardiovascular …, 1999 - Elsevier
Purpose. Intracoronary gamma or beta radiation from centrally located sources at the time of
overstretch balloon injury inhibits neointimal proliferation. In an effort to deliver …

Intracoronary radiation using radioisotope solution-filled balloons

J Weinberger - Herz, 1998 - search.proquest.com
A substantial body of experimental evidence suggests that local application of radiation at
sites of angioplasty or stent implantation prevents neointima formation. Recent initial clinical …

Monte Carlo dose simulation for intracoronary radiation therapy with a rhenium 188 solution-filled balloon with contrast medium

EH Kim, DH Moon, SJ Oh, CW Choi, SM Lim… - Journal of nuclear …, 2002 - Springer
Background The therapeutic efficacy of percutaneous transluminal coronary angioplasty is
limited by the incidence of restenosis. Intracoronary irradiation has shown to be effective in …