Radioembolization Dosimetry with total-body 90Y PET

G Costa, B Spencer, N Omidvari, C Foster… - Journal of Nuclear …, 2022 - Soc Nuclear Med
Transarterial radioembolization (TARE) is a locoregional radiopharmaceutical therapy
based on the delivery of radioactive 90Y microspheres to liver tumors. The importance of …

The impact of image reconstruction bias on PET/CT 90Y dosimetry after radioembolization

KN Tapp, WB Lea, MS Johnson, M Tann… - Journal of Nuclear …, 2014 - Soc Nuclear Med
PET/CT imaging after radioembolization is a viable method for determining the
posttreatment 90Y distribution in the liver. Low true-to-random coincidence ratios in 90Y PET …

[HTML][HTML] Phantom validation of quantitative Y-90 PET/CT-based dosimetry in liver radioembolization

M D'Arienzo, M Pimpinella, M Capogni, V De Coste… - EJNMMI research, 2017 - Springer
Background PET/CT has recently been shown to be a viable alternative to traditional post-
infusion imaging methods providing good quality images of 90 Y-laden microspheres after …

[HTML][HTML] 90Y post-radioembolization clinical assessment with whole-body Biograph Vision Quadra PET/CT: image quality, tumor, liver and lung dosimetry

KG Zeimpekis, L Mercolli, M Conti, H Sari… - European journal of …, 2024 - Springer
Purpose Evaluation of 90Y liver radioembolization post-treatment clinical data using a whole-
body Biograph Vision Quadra PET/CT to investigate the potential of protocol optimization in …

Feasibility assessment of yttrium-90 liver radioembolization imaging using amplitude-based gated PET/CT

DR Osborne, SN Acuff, ML Neveu, M Syed… - Nuclear Medicine …, 2018 - journals.lww.com
Purpose The usage of PET/computed tomography (CT) to monitor hepatocellular carcinoma
patients following yttrium-90 (90 Y) radioembolization has increased. Respiratory motion …

Validation of post‐treatment PET‐based dosimetry software for hepatic radioembolization of Yttrium‐90 microspheres

NM Maughan, J Garcia‐Ramirez, M Arpidone… - Medical …, 2019 - Wiley Online Library
Purpose Yttrium‐90 (90Y) microsphere radioembolization enables selective internal
radiotherapy for hepatic malignancies. Currently, there is no standard postdelivery imaging …

PET optimization for improved assessment and accurate quantification of 90Y‐microsphere biodistribution after radioembolization

JM Martí‐Climent, E Prieto, C Elosúa… - Medical …, 2014 - Wiley Online Library
Purpose: 90Y‐microspheres are widely used for the radioembolization of metastatic liver
cancer or hepatocellular carcinoma and there is a growing interest for imaging 90Y …

Study-parameter impact in quantitative 90-yttrium PET imaging for radioembolization treatment monitoring and dosimetry

A Goedicke, Y Berker, FA Verburg… - … on Medical Imaging, 2012 - ieeexplore.ieee.org
A small positron-generating branch in 90-Yttrium (90 Y) decay enables post-therapy dose
assessment in liver cancer radioembolization treatment. The aim of this study was to validate …

High quality imaging and dosimetry for yttrium-90 (90Y) liver radioembolization using a SiPM-based PET/CT scanner

H Duan, MH Khalaf, V Ferri, L Baratto… - European Journal of …, 2021 - Springer
Purpose Transarterial radioembolization (TARE) with yttrium-90 (90 Y) microspheres is a
liver-directed treatment for primary and secondary hepatic malignancies. Personalized …

Impact of image reconstruction method on dose distributions derived from 90Y PET images: phantom and liver radioembolization patient studies

X Hou, H Ma, PL Esquinas, C Uribe… - Physics in Medicine …, 2020 - iopscience.iop.org
PET images acquired after liver 90 Y radioembolization therapies are typically very noisy,
which significantly challenges both visualization and quantification of activity distributions …