Total-body PET multiparametric imaging of cancer using a voxelwise strategy of compartmental modeling
Quantitative dynamic PET with compartmental modeling has the potential to enable
multiparametric imaging and more accurate quantification than static PET imaging …
multiparametric imaging and more accurate quantification than static PET imaging …
Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation
In the context of oncology, dynamic PET imaging coupled with standard graphical linear
analysis has been previously employed to enable quantitative estimation of tracer kinetic …
analysis has been previously employed to enable quantitative estimation of tracer kinetic …
Total-body quantitative parametric imaging of early kinetics of 18F-FDG
Parametric imaging has been shown to provide better quantitation physiologically than SUV
imaging in PET. With the increased sensitivity from a recently developed total-body PET …
imaging in PET. With the increased sensitivity from a recently developed total-body PET …
Assessment of lesion detectability in dynamic whole-body PET imaging using compartmental and Patlak parametric mapping
N Zaker, F Kotasidis, V Garibotto… - Clinical nuclear …, 2020 - journals.lww.com
Purpose Hybrid dynamic imaging allows not only the estimation of whole-body (WB)
macroparametric maps but also the estimation of microparameters in the initial bed position …
macroparametric maps but also the estimation of microparameters in the initial bed position …
[HTML][HTML] Quantitative approaches of dynamic FDG-PET and PET/CT studies (dPET/CT) for the evaluation of oncological patients
A Dimitrakopoulou-Strauss, L Pan, LG Strauss - Cancer Imaging, 2012 - ncbi.nlm.nih.gov
Objectives: The use of dynamic positron emission tomography/computed tomography
(dPET/CT) studies with [18 F] deoxyglucose (FDG) in oncological patients is limited and …
(dPET/CT) studies with [18 F] deoxyglucose (FDG) in oncological patients is limited and …
First results on kinetic modelling and parametric imaging of dynamic 18F-FDG datasets from a long axial FOV PET scanner in oncological patients
Purpose To investigate the kinetics of 18 F-fluorodeoxyglucose (18 F-FDG) by positron
emission tomography (PET) in multiple organs and test the feasibility of total-body …
emission tomography (PET) in multiple organs and test the feasibility of total-body …
Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application
NA Karakatsanis, MA Lodge, AK Tahari… - Physics in Medicine …, 2013 - iopscience.iop.org
Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered
the standard clinical approach to diagnosis and treatment response monitoring for a wide …
the standard clinical approach to diagnosis and treatment response monitoring for a wide …
Feasibility of rapid multitracer PET tumor imaging
DJ Kadrmas, TC Rust - IEEE transactions on nuclear science, 2005 - ieeexplore.ieee.org
Positron emission tomography (PET) can characterize different aspects of tumor physiology
using various tracers. PET scans are usually performed using only one tracer since there is …
using various tracers. PET scans are usually performed using only one tracer since there is …
Dynamic multi-bed FDG PET imaging: feasibility and optimization
NA Karakatsanis, MA Lodge, Y Zhou… - 2011 IEEE nuclear …, 2011 - ieeexplore.ieee.org
Multi-Bed FDG PET/CT as applied to oncologic imaging is currently widely and routinely
used for assessment of localized and metastatic disease involvement. In the past, based on …
used for assessment of localized and metastatic disease involvement. In the past, based on …
Shortened acquisition protocols for the quantitative assessment of the 2-tissue-compartment model using dynamic PET/CT 18F-FDG studies
LG Strauss, L Pan, C Cheng, U Haberkorn… - Journal of Nuclear …, 2011 - Soc Nuclear Med
18F-FDG kinetics are quantified by a 2-tissue-compartment model. The routine use of
dynamic PET is limited because of this modality's 1-h acquisition time. We evaluated …
dynamic PET is limited because of this modality's 1-h acquisition time. We evaluated …