Quantitative accuracy of MR-based attenuation correction in whole-body PET/MR
G Schramm, J Langner, F Hofheinz, BB Baumann… - 2012 - Soc Nuclear Med
373 Objectives In 2010, a hybrid whole body PET/MR system (Philips Ingenuity TF PET/MR)
was installed at our institute. PET/MR is expected to offer many new possibilities in the field …
was installed at our institute. PET/MR is expected to offer many new possibilities in the field …
Accuracy of MR-based attenuation correction First experience with a whole-body PET/MR system
G Schramm, EM Brüning, J Langner, F Hofheinz… - … Resonance Materials in …, 2011 - hzdr.de
Purpose/Introduction: Sequential PET/MR scanners for whole body investigations have
been developed only recently and are starting to become commercially available. In 2011 …
been developed only recently and are starting to become commercially available. In 2011 …
Towards MR-based attenuation correction for whole-body PET/MR imaging
1469 Objectives: The success of whole-body (WB) PET/CT has led to an increased interest
also in combined PET/MR as a complementary hardware combination. However, neither …
also in combined PET/MR as a complementary hardware combination. However, neither …
Current image acquisition options in PET/MR
R Boellaard, HH Quick - Seminars in Nuclear Medicine, 2015 - Elsevier
Whole-body PET/MR hybrid imaging combines excellent soft tissue contrast and various
functional imaging parameters provided by MR with high sensitivity and quantification of …
functional imaging parameters provided by MR with high sensitivity and quantification of …
Variable lung density consideration in attenuation correction of whole-body PET/MRI
HR Marshall, FS Prato, L Deans… - Journal of Nuclear …, 2012 - Soc Nuclear Med
Present attenuation-correction algorithms in whole-body PET/MRI do not consider variations
in lung density, either within or between patients; this may adversely affect accurate …
in lung density, either within or between patients; this may adversely affect accurate …
MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation-and atlas-based methods
M Hofmann, I Bezrukov, F Mantlik… - Journal of Nuclear …, 2011 - Soc Nuclear Med
PET/MRI is an emerging dual-modality imaging technology that requires new approaches to
PET attenuation correction (AC). We assessed 2 algorithms for whole-body MRI-based AC …
PET attenuation correction (AC). We assessed 2 algorithms for whole-body MRI-based AC …
Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
Purpose The objective of this study was to evaluate the performance of the built-in MR-
based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF …
based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF …
Lung attenuation coefficient estimation using Maximum Likelihood reconstruction of attenuation and activity for PET/MR attenuation correction
Y Berker, A Salomon, F Kiessling… - 2012 IEEE Nuclear …, 2012 - ieeexplore.ieee.org
MR-based PET attenuation correction using segmented MR images is a promising approach
to compensating for the lack of a transmission source in PET/MR and solving the problem of …
to compensating for the lack of a transmission source in PET/MR and solving the problem of …
MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuation
A Akbarzadeh, MR Ay, A Ahmadian… - Annals of nuclear …, 2013 - Springer
Abstract Objective Hybrid PET/MRI presents many advantages in comparison with its
counterpart PET/CT in terms of improved soft-tissue contrast, decrease in radiation …
counterpart PET/CT in terms of improved soft-tissue contrast, decrease in radiation …
MR-based attenuation correction for whole-body MR/PET
A Martínez-Möller, M Souvatzoglou, N Navab… - 2008 - Soc Nuclear Med
260 Objectives: To perform scatter and attenuation correction in future whole-body MR/PET
devices, it is necessary to determine an attenuation map with the attenuating factors for 511 …
devices, it is necessary to determine an attenuation map with the attenuating factors for 511 …