[PDF][PDF] Technetium-99m MIBI uptake in recurrent parathyroid carcinoma and brown tumors

G Lu, WJ Shih, JY Xiu - Journal of Nuclear Medicine, 1995 - Soc Nuclear Med
DISCUSSION This patient's parathyroid malignancy had histological evidence of carcinoma
with invasion of adjacent thyroid tissue as well as recurrent clinical manifestations of hyper …

TI-201 uptake in brown tumors of hyperparathyroidism

H DURAK, T ARAS, CEM SUNGUR… - Clinical Nuclear …, 1991 - journals.lww.com
TI-201 chloride bone scans were performed on nine patients with primary
hyperparathyroidism just after TI-201 and Tc-99m parathyroid subtraction scintigraphy. Bone …

A false-positive localization of a parathyroid adenoma with technetium Tc 99m sestamibi scan secondary to a thyroid follicular carcinoma

WGM Koss, MR Brown, JF Balfour - Archives of Surgery, 1996 - jamanetwork.com
Using technetium Tc 99m sestamibi for localization of a parathyroid adenoma in primary
hyperparathyroidism, we describe the first reported case of increased uptake due to a …

Visualization of a parathyroid adenoma with Tc-99m MIBI in a case with iodine saturation and impaired thallium uptake

K OSMANAGAOGLU, K Schelstraete… - Clinical nuclear …, 1993 - journals.lww.com
Visualization of a Parathyroid Adenoma with Page 1 CLINICAL NUCLEAR MEDICINE
Volume 18, Number 3, pp 2 l4–2 l6 C) 1993, JB Lippincott Co, Visualization of a Parathyroid …

Nonfunctional parathyroid carcinoma

Y Nakamura, H Kataoka, T Sakoda, Y Horie… - International journal of …, 2010 - Springer
A 65-year-old female patient was admitted to our hospital presenting with a superior
mediastinal big mass that was elastic, hard, and painless. Laboratory data including serum …

Uptake of Tc-99m sestamibi by brown tumors in a patient with primary hyperparathyroidism

JR ANNAMALAI MUTHIAH, JG Kalani… - Clinical nuclear …, 1998 - journals.lww.com
This article discusses a case of Tc-99m sestamibi uptake by brown tumors in a patient with
primary hyperparathyroidism. Brown tumors are characteristic tumors of …

A case of parathyroid carcinoma visualized on Tc-99m-sestamibi scintigraphy

RM Aigner, GF Fueger, S Lax - Nuklearmedizin …, 1997 - thieme-connect.com
Recent studies indicate that Tc-99m-Sestamibi (MIBI, DuPont Pharma) is a useful tracer for
detecting parathyroid adenomas. We present a patient with focal Tc-99m-MIBI uptake in …

Rapid washout of technetium-99m-MIBI from a large parathyroid adenoma.

F Bénard, B Lefebvre, F Beuvon… - Journal of Nuclear …, 1995 - europepmc.org
We report a case of rapid 99mTc-methoxyisobutylisonitrile (MIBI) clearance from a
parathyroid adenoma. A double-phase 99mTc-MIBI parathyroid scintigraphy was performed …

Technetium-99m sestamibi uptake in a maxillary brown tumor

IW Gayed, SM Elshazly, RS Vang… - Clinical nuclear …, 2001 - journals.lww.com
Brown tumors have been reported to take up Tl-201 when dual-tracer parathyroid
scintigraphy using Tl-201 and Tc-99m pertechnetate was performed. With the change to the …

Metastatic thyroid cancer visualized on technetium pertechnetate and iodine-131 scintigraphy

N Verma, S Singh-Wadhwa… - Clinical nuclear medicine, 2002 - journals.lww.com
Metastatic Thyroid Cancer Visualized on Technetium Pertechne... : Clinical Nuclear Medicine
Metastatic Thyroid Cancer Visualized on Technetium Pertechnetate and Iodine-131 Scintigraphy …