[PDF][PDF] A 133Xe Transmission Source

EL Darter - Journal of Nuclear Medicine, 1974 - Soc Nuclear Med
METHOD The filling device consists of a ½-in. bolt placed in a ½-in. hole previously
drilled through the center of a pair of two lateral walls. During the assembly, epoxy glue was …

[PDF][PDF] A Multiple-Dose 133Xe Solution “Generator”: The Disposable Glass Ampule Equilibration Chamber

RG Carroll, RA Berke, RT Anger, G Levine… - Journal of Nuclear …, 1973 - Soc Nuclear Med
jiun/C0NCISE COMMUNICATION Page 1 tional Laboratory's glass ampule and a rubber and
metal apparatus to produce xenon saline solution (6). Subsequently,Loken's group has used a …

[PDF][PDF] System for handling and dispensing 133Xe

RE Snyder, TR Overton - Journal of Nuclear Medicine, 1973 - Soc Nuclear Med
MATERIALS AND METHODS Apparatus. The transfer-dispenser system has three major
components:(A) a transfer device,(B) a special storage syringe for the xenon solution, and …

A Simplified Technic for the Transfer of 133Xe

A Marks, I Chervony - Radiology, 1968 - pubs.rsna.org
During the course of developing a technic for a steady state method of measuring ventilation-
perfusion relationships utilizing 133Xe, it became apparent that the described methods for …

[CITATION][C] Message From The Acting President

J Hall - Journal of Nuclear Medicine Technology, 1989 - Soc Nuclear Med
Paul Cole would Athens, Texas have provided, I have tried to enact the policies and goals
that Paul originally developed. I am pleased to report that Paul has been posthumously …

[PDF][PDF] jiun/C0NCISE COMMUNICATION

HC Wieland, GM Grames, C Jansen… - The Journal of Nuclear …, 1960 - Citeseer
METHOD The tagging vial as received from 3M is double ended with a large central
chamber in continuity with the silver end. A small chamber at the gold end con tains ion …

[CITATION][C] i TECHNOLOGIST sec-non PROGRAM i

T Student - Journal of Nuclear Medicine Technology - search.proquest.com
The Business Center is located in the concourse walkway between the south and west
towers of the convention center. The Business Center will be open during Annual Meeting …

Isodose Distributions for a 1,100-Curie Cobalt60 Unit

SO Fedoruk, HE Johns, TA Watson - Radiology, 1953 - pubs.rsna.org
In August 1951, 1,100 curies of cobalt60 were loaded into the treatment head of a therapy
unit in the University Hospital, Saskatoon. This unit was manufactured in Saskatoon by the …

[CITATION][C] A 25th Anniversary Address: Presented at the 42nd Annual Meeting of the Society of Nuclear Medicine, Minneapolis, Minnesota on June 12, 1995

GA Wood - Journal of Nuclear Medicine Technology, 1995 - Soc Nuclear Med
While it has been said that the longest jour-ney begins with a single step, we are not usually
reminded of the hard work and planning that goes into that first step. Twenty-five years ago …

[CITATION][C] TWENTY YEARS AND GROWING

K Thomas - Journal of Nuclear Medicine Technology, 1990 - Soc Nuclear Med
(J Nucl Med Technol1985; 2: 110-112) and review the historical progress of the
Technologist Section from its early inception through its 15th anniversary. The foundation of …