Effect of scintillation camera nonuniformity on ejection fraction measurements.

E Busemann-Sokole, TJ Farrell… - Journal of Nuclear …, 1985 - europepmc.org
A rotating cardiac phantom with three possible ejection fraction (EF) values was used in
conjunction with a scintillation camera employing energy correction and count skim …

On-line corrections for factors that affect uniformity and linearity

GH Simmons - Journal of Nuclear Medicine Technology, 1988 - Soc Nuclear Med
This is the second in a series of four continuing education articles on scintillation camera
technology. After reading this article, the reader should be able to: 1) discuss the causes for …

Quantitative assessment of linearity of scintillation cameras.

KH Lee - Radiology, 1980 - pubs.rsna.org
A method is proposed for quantifying the intrinsic linearity of a scintillation camera for quality
assurance purposes. The distance between adjacent holes in the image of a Smith …

[PDF][PDF] Correction for field nonuniformity in scintillation cameras through removal of spatial distortion

G Muehllehner, JG Colsher… - journal of Nuclear Medicine, 1980 - Soc Nuclear Med
MUEHLLEHNER, COLSHER, AND STOUB if a circular area 20 mm in diameter
iscompressed by 0.4 mm toward its center from all directions (as might be the case over the …

[PDF][PDF] The effect of photon energy on tests of field uniformity in scintillation cameras: Concise communication

JT Lewis, RA Neff, H Nishiyama… - Journal of Nuclear …, 1978 - Soc Nuclear Med
We investigated the effect of photon energy in testing field uniformity using two cameras of
types not previously reported in the literature. They will be referred to as Camera A and …

A precise method for correcting count‐rate losses in scintillation cameras

MT Madsen, RJ Nickles - Medical physics, 1986 - Wiley Online Library
Quantitative studies performed with scintillation detectors often require corrections for lost
data because of the finite resolving time of the detector. Methods that monitor losses by …

Spontaneous variability of left ventricular ejection fraction assessed with the Cardioscint

P Broadhurst, XJ Liu, PMM Cashman… - Nuclear medicine …, 1992 - journals.lww.com
A miniature, non-imaging caesium iodide nuclear probe optically coupled to a photodiode
(the'Cardioscint') has been developed which, in conjunction with a modified personal …

A new method for quantification of image distortion due to pile-up in scintillation cameras

C Ceberg, I Larsson, SE Strand - European journal of nuclear medicine, 1991 - Springer
Abstract Characterization of the count-rate performance of scintillation cameras should
include not only the specification of count losses. At high count rates, there is also an image …

A new method for the correction of gamma camera nonuniformity due to spatial distortion

TK Johnson, C Nelson, DL Kirch - Physics in Medicine & Biology, 1996 - iopscience.iop.org
A methodology for correcting scintillation camera nonuniformity resulting from spatial
linearity distortion is described. The method simultaneously corrects for both variations in …

[PDF][PDF] Component resolution indices for scintillation camera systems

VA Brookeman - Journal of Nuclear Medicine, 1975 - Soc Nuclear Med
for three Anger camerasystems, measuredwith Page 1 From published overall resolution
indices for three Anger camerasystems, measuredwith three straight-bore collimators and …