3D List-mode Image Reconstruction for the EasyPET prototype

SÃ Diniz, N Ferreira, P Correia, P EncarnaÃ, J Menoita… - 2018 - Soc Nuclear Med
1785 Objectives: To present the first results of 3D iterative image reconstruction algorithms
developed for EasyPET, a 3D PET prototype with variable spatial sampling. The easyPET is …

The rotate-and-slant projector for PET: Fully-3D OSEM as fast as FORE 2D-OSEM

D Kadrmas - 2007 - Soc Nuclear Med
319 Objectives: One of the greatest challenges facing iterative fully-3D PET reconstruction is
the issue of long reconstruction times due to the large data size as compared to 2D mode. A …

A practical, semi-experimental system matrix for 2-D PET image reconstruction: Comparison with a geometrical model

L Fin, P Bailly, J Daouk… - 2008 IEEE Nuclear …, 2008 - ieeexplore.ieee.org
An accurate system matrix is an important component in statistical PET image
reconstruction. Indeed, inaccurate projection-backprojection may wrongly distribute …

Optimization of PET image quality by means of 3D data acquisition and iterative image reconstruction

J Doll, J Zaers, H Trojan, ME Bellemann… - Nuklearmedizin …, 1998 - europepmc.org
Purpose In the recent past, several algorithms have been developed in order to transform
3D sinograms acquired at volume PET systems into 2D data sets. These methods offer the …

Initial evaluation of a direct 4D PET parametric image reconstruction method

J Yan, B Planeta-Wilson, R Carson - 2009 - Soc Nuclear Med
1462 Objectives The goal of this study is to evaluate an algorithm for direct reconstruction of
PET parametric images from a one-tissue (1T) kinetic model. Methods Replicates of a 10-cm …

Fully 3D MAP reconstruction for microPET data with continuous bed motion

J Qi - 2006 - Soc Nuclear Med
1485 Objectives: MicroPET is widely used for imaging small animals for biological research.
Current microPET scanners have a limited axial field-of-view (FOV). Multiple bed positions …

Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners

SR Cherry, M Dahlbom… - Physics in Medicine & …, 1992 - iopscience.iop.org
A fully 3D reconstruction algorithm based on filtered backprojection was evaluated for the
reconstruction of data obtained with multi-slice positron emission tomography (PET) …

Dedicated 3D list-mode reconstruction for whole-body PET

A Lougovski, J Langner, F Hofheinz, EM Brüning, J Hoff - Nuklearmedizin, 2011 - hzdr.de
Although all currently available PET scanners support 3D acquisition protocols, full 3D
image reconstruction is only rarely available in clinical PET. Usually, Fourier rebinning is …

Quantitative performance evaluation of a high-resolution high sensitivity PET system: single vs. multi-mouse imaging

P Mollet, K Braeckman, K Deprez, J Courtyn, S Neyt - 2021 - Soc Nuclear Med
1438 Objectives: A reproducible and high throughput workflow is often a must when large
cohorts of mice need to be scanned. A strategy to increase imaging throughput is to image …

Accelerated list-mode 3D-OSEM reconstruction for PET on a graphics processing unit

G Pratx, P Olcott, G Chinn, C Levin - 2006 - Soc Nuclear Med
526 Objectives: We implemented an accelerated version of list-mode 3D ordered subset
expectation maximization (OSEM) on a graphics processing unit (GPU). GPUs, present in …