[PDF][PDF] Bleeding rates necessary for detecting acute gastrointestinal bleeding with technetium-99m-labeled red blood cells in an experimental model

DA Thorne, FL Datz, K Remley… - Journal of nuclear …, 1987 - Soc Nuclear Med
MATERIALS AND METHODS Fourteen dogs, each weighing 15-25 kg, were anesthetized
with sodium pentobarbital. A catheter was inserted and se cured into the lumen of the …

[PDF][PDF] Evaluation of gastrointestinal bleeding by red blood cells labeled in vivo with technetium-99m

GG Winzelberg, KA McKusick, HW Strauss… - Journal of Nuclear …, 1979 - Soc Nuclear Med
MATERIALS AND METHODS Two groups of patients were studied. The first con sisted of 28
control patients,(12F+ I6M), ages 28 through 65 yr, undergoing gated blood-pool scintigrams …

Detection of gastrointestinal bleeding with 99mTc-labeled red blood cells

GG Winzelberg, KA McKusick, JW Froelich… - Seminars in Nuclear …, 1982 - Elsevier
Using a modified in vivo Tc-99m red cell labeling technique, gastrointestinal (GI) bleeding
scintigraphy was performed in 100 patients with GI bleeding. Sixty-two patients with melena …

[PDF][PDF] Prognostic significance of late imaging results in technetium-99m-labeled red blood cell gastrointestinal bleeding studies with early negative images

AF Jacobson, MD Cerqueira - Journal of Nuclear Medicine, 1992 - Soc Nuclear Med
METHODS One hundred six consecutive Gl bleeding studies with"" re labeled RBCs
performed during a 5-yr period were retrospectively reviewed. All studies were acquired on …

99mTc red blood cells for detection of gastrointestinal bleeding: experience with 80 patients

KA McKusick, J Froelich, RJ Callahan… - American Journal of …, 1981 - Am Roentgen Ray Soc
Imaging was done in 80 patients with gastrointestinal hemorrhage using red blood cells
labeled with 99mTc by a modified in vivo technique. Bleeding was detected in 65% of 40 …

Localization of lower gastrointestinal bleeding using in vivo technetium‐99m‐labelled red blood cell scintigraphy

ML Nicholson, JP Neoptolemos, JF Sharp… - British journal of …, 1989 - Wiley Online Library
Technetium‐99m‐labelled red blood cell scintigraphy was used in the investigation of 41
patients with major rectal haemorrhage. Red cells were labelled in vivo with technetium …

Localization of lower gastrointestinal hemorrhage: experience with red blood cells labeled in vitro with technetium Tc 99m

PM Orecchia, EK Hensley, PT McDonald… - Archives of …, 1985 - jamanetwork.com
• Seventy-six patients clinically suspected of having lower gastrointestinal bleeding were
studied by scintigraphy utilizing red blood cells labeled in vitro with technetium Tc 99m …

Detection of Gastrointestinal Bleeding Sites: Use of In Vitro Technetium Tc 99m—Labeled RBCs

SR Bunker, JM Brown, RJ McAuley, RJ Lull… - JAMA, 1982 - jamanetwork.com
Sixteen patients clinically suspected of having gastrointestinal hemorrhage were studied by
abdominal scintigraphy with RBCs labeled in vitro with technetium Tc 99m. Ten of 11 …

An evaluation of 99mTc-labeled red blood cell scintigraphy for the detection and localization of gastrointestinal bleeding sites

JA Markisz, D Front, HD Royal, B Sacks, JA Parker… - Gastroenterology, 1982 - Elsevier
99m Technetium-labeled red blood cell scintigraphy was performed upon 39 patients with
clinical evidence for acute lower gastrointestinal bleeding from an unknown source …

Detection of gastrointestinal blood loss with 99mTc-labeled, heat-treated red blood cells.

P Som, ZH Oster, HL Atkins, AG Goldman, DF Sacker… - Radiology, 1981 - pubs.rsna.org
Studies in dogs showed that heat-treated 99mTc-labeled red blood cells (HT/RBC) afford a
highly sensitive means of detecting gastrointestinal bleeding as low as 0.12 ml/min., which …