Uptake of F-18-fluoroethyl-L-tyrosine and H-3-L-methionine in focal cortical ischemia

D Bauer, G Stoffels, D Pauleit, C Palm, K Hamacher… - 2006 - Soc Nuclear Med
1160 Objectives: C-11-methionine (MET) is particularly useful in brain tumor diagnosis but
unspecific uptake eg in cerebral ischemia has been reported (1). The F-18-labeled amino …

Differential uptake of [18F] FET and [3H] l-methionine in focal cortical ischemia

D Salber, G Stoffels, D Pauleit, G Reifenberger… - Nuclear medicine and …, 2006 - Elsevier
Amino acids such as [11C-methyl] l-methionine are particularly useful in brain tumor
diagnosis, but unspecific uptake (eg, in cerebral ischemia) has been reported. O-(2-[18F] …

Comparison of O-(2-18F-fluoroethyl)-L-tyrosine and L-3H-methionine uptake in cerebral hematomas

D Salber, G Stoffels, AM Oros-Peusquens… - Journal of nuclear …, 2010 - Soc Nuclear Med
Radiolabeled amino acids are useful for brain tumor diagnosis, but unspecific uptake near
the cerebral hematoma may complicate the differentiation of a neoplastic from a …

High-and moderately high-methionine uptake demonstrated by PET in a patient with a subacute cerebral infarction

A Nagano-Saito, T Kato, T Wakabayashi… - Annals of nuclear …, 2001 - Springer
In patients with cerebral tumors, high accumulations of l-methyl-11 C-methionine (11 C-Met)
have been reported in some cases of cerebral ischemic disease, but no high accumulations …

Differential uptake of FET, MET and deoxyglucose in cerebral abscesses in rats

D Salber, K Hamacher, G Stoffels, D Pauleit, H Coenen… - 2007 - Soc Nuclear Med
1165 Objectives: The amino acid O-(2-[18F] fluorethyl)-L-tyrosine (FET) has been shown to
be a powerful tracer for brain tumor imaging. Experimental studies have shown that there is …

Differential uptake of O-(2-18F-fluoroethyl)-L-tyrosine, L-3H-methionine, and 3H-deoxyglucose in brain abscesses

D Salber, G Stoffels, D Pauleit… - Journal of Nuclear …, 2007 - Soc Nuclear Med
The amino acid O-(2-18F-fluoroethyl)-l-tyrosine (18F-FET) has been shown to be a useful
tracer for brain tumor imaging. Experimental studies demonstrated no uptake of 18F-FET in …

Normal values for uptake rate constant (Ki) for [18F]-fluoroethyl-L-tyrosine (FET) in brain

D Bailey, G Schembri, J Yeow, M Johnson… - 2013 - Soc Nuclear Med
13 Objectives To measure K i (%/min) from Patlak-Rutland graphical analysis in normal
brain from grey matter (GM) and white matter (WM) to enable uptake in tumour regions to be …

Treatment-related uptake of O-(2-18F-fluoroethyl)-l-tyrosine and l-[methyl-3H]-methionine after tumor resection in rat glioma models

S Geisler, C Stegmayr, N Niemitz… - Journal of nuclear …, 2019 - Soc Nuclear Med
Assessment of residual tumor after resection of cerebral gliomas can be difficult with MRI
and may be improved by amino acid PET. The aim of this experimental study was to …

O-(2-[18F]Fluoroethyl)-l-tyrosine and l-[methyl-11C]methionine uptake in brain tumours: initial results of a comparative study

WA Weber, HJ Wester, AL Grosu, M Herz… - European journal of …, 2000 - Springer
O-(2-[18 F] Fluoroethyl)-l-tyrosine (FET) is a recently described amino acid analogue that
has shown high accumulation in animal tumours. The aim of this study was to compare the …

Amino Acid PET Tracer Accumulation in Cortical Ischemia: An Interesting Case

C Rottenburger, S Doostkam, M Prinz… - Clinical Nuclear …, 2010 - journals.lww.com
The use of amino acid PET tracers like F-18 fluorethyltyrosine (FET) in the diagnostic workup
of brain tumors has gained widespread acceptance. We report a case of a man who initially …