Does resolution modeling during reconstruction improve the DAT measurement on a high resolution PET?
466 Objectives Resolution modeling is known to improve quantification in small structures
by reducing the partial-volume effects. The aim of this work is to assess the impact of a fast …
by reducing the partial-volume effects. The aim of this work is to assess the impact of a fast …
Performance of the resolution recovery method on the Ingenuity PET/CT
1836 Objectives The finite resolution of PET results in partial volume effects (PVE). PVE
correction is a requisite for improvement of PET quantification of small structures. The aim of …
correction is a requisite for improvement of PET quantification of small structures. The aim of …
Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET
577 Objectives In this study we compare an OSEM algorithm incorporating measured point
spread functions (PSF) modeling for resolution recovery, and two post-reconstruction …
spread functions (PSF) modeling for resolution recovery, and two post-reconstruction …
Impact of Reconstruction Algorithms on the Quantitative Evaluation of 11C-PiB PET/CT Studies
1459 Introduction: Modern PET/CT with better instrumentation and software could possibly
produce more accurate diagnosis for brain studies such as in Alzheimer disease. The …
produce more accurate diagnosis for brain studies such as in Alzheimer disease. The …
High resolution image reconstruction (point spread function based) in FDG brain PET
M Reimold, C Pfannenberg, J Kupferschläger, R Bares - 2012 - Soc Nuclear Med
2341 Objectives Point spread function (PSF) based image reconstruction increases
apparent spatial resolution at the expense of possible edge artifacts. Our aim was to …
apparent spatial resolution at the expense of possible edge artifacts. Our aim was to …
Validations for MR-based partial volume correction for brain PET imaging
K Matsubara, M Ibaraki, T Maeda, T Kinoshita - 2016 - Soc Nuclear Med
1930 Objectives Several methods to correct partial volume effect (PVE), based on magnetic
resonance (MR) images, have been proposed and utilized widely in PET studies. However …
resonance (MR) images, have been proposed and utilized widely in PET studies. However …
Partial volume correction strategies for parametric images
P Zanotti-Fregonara, CT Li, C Comtat, S Zoghbi… - 2013 - Soc Nuclear Med
2041 Objectives Partial volume correction (PVC) is necessary in brain PET studies to
differentiate an artefactual reduction in radiotracer uptake due to cerebral atrophy from a true …
differentiate an artefactual reduction in radiotracer uptake due to cerebral atrophy from a true …
Evaluation of the Benefit of Partial Volume Correction for High Resolution PET Scanners
E Raptis, LM Parkes… - 2019 IEEE Nuclear …, 2019 - ieeexplore.ieee.org
The benefit of partial volume correction (PVC) within and post image reconstruction for high
resolution PET scanners was examined. Listmode data from a realistic simulation of the …
resolution PET scanners was examined. Listmode data from a realistic simulation of the …
[HTML][HTML] Partial volume correction of brain PET studies using iterative deconvolution in combination with HYPR denoising
Background Accurate quantification of PET studies depends on the spatial resolution of the
PET data. The commonly limited PET resolution results in partial volume effects (PVE) …
PET data. The commonly limited PET resolution results in partial volume effects (PVE) …
[HTML][HTML] Brain partial volume correction with point spreading function reconstruction in high-resolution digital PET: comparison with an MR-based method in FDG …
M Ibaraki, K Matsubara, Y Shinohara… - Annals of Nuclear …, 2022 - Springer
Objective In quantitative positron emission tomography (PET) of the brain, partial volume
effect due mainly to the finite spatial resolution of the PET scanner (> 3 mm full width at half …
effect due mainly to the finite spatial resolution of the PET scanner (> 3 mm full width at half …