Does resolution modeling during reconstruction improve the DAT measurement on a high resolution PET?

C Leroy, MJ Ribeiro, F Sureau, E Artiges, V Brulon… - 2009 - Soc Nuclear Med
466 Objectives Resolution modeling is known to improve quantification in small structures
by reducing the partial-volume effects. The aim of this work is to assess the impact of a fast …

Performance of the resolution recovery method on the Ingenuity PET/CT

S Golla, A Lammertsma, R Boellaard - 2015 - Soc Nuclear Med
1836 Objectives The finite resolution of PET results in partial volume effects (PVE). PVE
correction is a requisite for improvement of PET quantification of small structures. The aim of …

Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET

A Le Pogam, A Alessio, B Kandel, A Kirov, O Barret… - 2010 - Soc Nuclear Med
577 Objectives In this study we compare an OSEM algorithm incorporating measured point
spread functions (PSF) modeling for resolution recovery, and two post-reconstruction …

Impact of Reconstruction Algorithms on the Quantitative Evaluation of 11C-PiB PET/CT Studies

S Mansor, M Hamdi, S Flores, Z Tu, J Perlmutter… - 2020 - Soc Nuclear Med
1459 Introduction: Modern PET/CT with better instrumentation and software could possibly
produce more accurate diagnosis for brain studies such as in Alzheimer disease. The …

High resolution image reconstruction (point spread function based) in FDG brain PET

M Reimold, C Pfannenberg, J Kupferschläger, R Bares - 2012 - Soc Nuclear Med
2341 Objectives Point spread function (PSF) based image reconstruction increases
apparent spatial resolution at the expense of possible edge artifacts. Our aim was to …

Validations for MR-based partial volume correction for brain PET imaging

K Matsubara, M Ibaraki, T Maeda, T Kinoshita - 2016 - Soc Nuclear Med
1930 Objectives Several methods to correct partial volume effect (PVE), based on magnetic
resonance (MR) images, have been proposed and utilized widely in PET studies. However …

Partial volume correction strategies for parametric images

P Zanotti-Fregonara, CT Li, C Comtat, S Zoghbi… - 2013 - Soc Nuclear Med
2041 Objectives Partial volume correction (PVC) is necessary in brain PET studies to
differentiate an artefactual reduction in radiotracer uptake due to cerebral atrophy from a true …

Evaluation of the Benefit of Partial Volume Correction for High Resolution PET Scanners

E Raptis, LM Parkes… - 2019 IEEE Nuclear …, 2019 - ieeexplore.ieee.org
The benefit of partial volume correction (PVC) within and post image reconstruction for high
resolution PET scanners was examined. Listmode data from a realistic simulation of the …

[HTML][HTML] Partial volume correction of brain PET studies using iterative deconvolution in combination with HYPR denoising

SSV Golla, M Lubberink, BNM van Berckel… - EJNMMI research, 2017 - Springer
Background Accurate quantification of PET studies depends on the spatial resolution of the
PET data. The commonly limited PET resolution results in partial volume effects (PVE) …

[HTML][HTML] Brain partial volume correction with point spreading function reconstruction in high-resolution digital PET: comparison with an MR-based method in FDG …

M Ibaraki, K Matsubara, Y Shinohara… - Annals of Nuclear …, 2022 - Springer
Objective In quantitative positron emission tomography (PET) of the brain, partial volume
effect due mainly to the finite spatial resolution of the PET scanner (> 3 mm full width at half …