[PDF][PDF] Indium-111-labeled leukocyte scintigraphy in hemodialysis access-site infection

CJ Palestro, A Vega, CK Kim… - Journal of Nuclear …, 1990 - Soc Nuclear Med
RESULTS Fifteen of the thirty access sites were infected, all microbiobogically confirmed; of
the fifteen access sites classified as infection free, absence of infection was microbiologically …

In-111-leukocyte scintigraphy for detection of infection associated with peritoneal dialysis catheters.

SL Kipper, RW Steiner, KF Witztum, RM Basarab… - Radiology, 1984 - pubs.rsna.org
In-111-labeled leukocytes were administered to 13 patients on continuous ambulatory
peritoneal dialysis in order to locate catheter-associated infections. Using a marker to …

[CITATION][C] Hidden clotted vascular access infection diagnosed by fluorodeoxyglucose positron emission tomography

MG Carlos, R Juliana, N Matilde, V Marcelo… - …, 2008 - Wiley Online Library
Clotted arteriovenous grafts can be a source of sepsis in dialysis patients, but this sort of
infection is usually silent, chronic and very difficult to diagnose. 1, 2 Fluorodeoxyglucose …

[CITATION][C] FDG PET diagnosis of septic kidney in a renal transplant patient

Z Kaya, J Kotzerke, F Keller - Transplant International, 1999 - Springer
Sir: Localization of septic foci is often difficult. We would like to report on our recent
experience with a 61-year-old patient who was admitted with fever and rising serum …

Uptake of In-111 Labeled Leukocytes by Lymphocele A Cause of False-Positive Vascular Graft Infection

CJ CHUNG, AA WILSON, JW MELTON… - Clinical Nuclear …, 1992 - journals.lww.com
In-111 labeled leukocyte scintigraphy is a sensitive test for the diagnosis of prosthetic
vascular graft infections. However, several causes of false-positive results have been …

Silent infection in clotted hemodialysis access grafts.

JC Ayus, D Sheikh-Hamad - Journal of the American Society of …, 1998 - journals.lww.com
Thrombotic and infectious complications are frequent causes of hemodialysis vascular
access failure and contribute considerably to the cost of care for chronic hemodialysis …

Is there a role for gallium-67 citrate SPECT/CT, in patients with renal impairment or who are renal transplant recipients, in identifying and localizing suspected infection …

E Nowosinska, S Navalkissoor… - World Journal of …, 2015 - thieme-connect.com
To assess the added value of single-photon emission computed tomography/computed
tomography (SPECT/CT) in patients with end-stage renal failure (ESRF) or renal transplant …

[PDF][PDF] Localization of 67Ga in renal microabscesses

HM Park, AE Forry, RL Sagalowski - Journal of Nuclear Medicine, 1977 - Soc Nuclear Med
Postoperative urine cultures from a ureterostomic catheter disclosed Pseudomonas
aeruginosa. The patient was treated with Vibramycin and carbenicillin and was discharged …

Peritoneal scintigraphy in the diagnosis of adhesions

S Gudit, P Sudhakar, R Ram, N Prasad… - Peritoneal Dialysis …, 2010 - journals.sagepub.com
Editor: Some patients are able to return to continuous ambulatory peritoneal dialysis (CAPD)
after severe episodes of peritonitis. In other patients, peritoneal adhesions may prevent …

[PDF][PDF] Imaging of peritoneal catheter tunnel infection using positron-emission tomography

AH Tzamaloukas - Advances in Peritoneal Dialysis, 2010 - academia.edu
Exit-site infections (ESIs) and tunnel infections of the peritoneal dialysis (PD) catheter are
ongoing problems. Exit-site infections are routinely diagnosed by clinical examination (1) …