[CITATION][C] Reply: Flare Phenomenon in O-(2-[18F]-Fluoroethyl)-L-Tyrosine PET After Resection of Gliomas

CP Filss, C Stegmayr, P Lohmann… - Journal of Nuclear …, 2020 - Soc Nuclear Med
(7, 8). In a preclinical study of focal cortical ischemia induction in rats, increased uptake of
18F-FET was observed in the ischemic lesions for up to 7 days and the lesion-to-brain (L/B) …

Flare phenomenon in O-(2-18F-fluoroethyl)-l-tyrosine PET after resection of gliomas

CP Filss, AK Schmitz, G Stoffels… - Journal of nuclear …, 2020 - Soc Nuclear Med
PET using O-(2-18F-fluoroethyl)-l-tyrosine (18F-FET) is useful to detect residual tumor tissue
after glioma resection. Recent animal experiments detected reactive changes in 18F-FET …

Flare phenomenon in O-(2-[18F]-fluoroethyl)-L-tyrosine PET after resection of gliomas: potential contribution from postoperative ischemia

SA Nabavizadeh, IM Nasrallah… - Journal of Nuclear …, 2020 - Soc Nuclear Med
TO THE EDITOR: We read with interest the recent article by Koopman et al. entitled
''Performance of Digital PET Compared with High-Resolution Conventional PET in Patients …

Strategy based on kinetics of O-(2-[18F] fluoroethyl)-L-tyrosine ([18F] FET)

M Kameyama, Y Umeda-Kameyama - European journal of nuclear …, 2016 - Springer
Dear Sir, We read with great interest the article by Albert et al. published in the European
Journal of Nuclear Medicine and Molecular Imaging entitled “Early static 18F-FET-PET …

Treatment-related uptake of O-(2-18F-fluoroethyl)-l-tyrosine and l-[methyl-3H]-methionine after tumor resection in rat glioma models

S Geisler, C Stegmayr, N Niemitz… - Journal of nuclear …, 2019 - Soc Nuclear Med
Assessment of residual tumor after resection of cerebral gliomas can be difficult with MRI
and may be improved by amino acid PET. The aim of this experimental study was to …

Role of O-(2-18F-fluoroethyl)-L-tyrosine PET as a diagnostic tool for detection of malignant progression in patients with low-grade glioma

N Galldiks, G Stoffels, MI Ruge, M Rapp… - Journal of Nuclear …, 2013 - Soc Nuclear Med
In patients with low-grade glioma (LGG) of World Health Organization (WHO) grade II, early
detection of progression to WHO grade III or IV is of high clinical importance because the …

Reply to “[18F]-fluoro-ethyl-L-tyrosine PET: a valuable diagnostic tool in neuro-oncology, but not all that glitters is glioma” by Hutterer et al.

KJ Langen, N Galldiks - Neuro-oncology, 2013 - academic.oup.com
Dear Editor, We read with great interest the article entitled “[18F]-fluoro-ethyl-L-tyrosine PET:
a valuable diagnostic tool in neuro-oncology, but not all that glitters is glioma” 1 in Neuro …

Uptake of O-(2-[18F] fluoroethyl)-L-tyrosine in reactive astrocytosis in the vicinity of cerebral gliomas

MD Piroth, J Prasath, A Willuweit, G Stoffels… - Nuclear medicine and …, 2013 - Elsevier
Abstract PET using O-(2-[18 F] fluoroethyl)-L-tyrosine (18 F-FET) allows improved imaging of
tumor extent of cerebral gliomas in comparison to MRI. In experimental brain infarction and …

Prognostic value of O-(2-18F-fluoroethyl)-L-tyrosine PET and MRI in low-grade glioma

FW Floeth, D Pauleit, M Sabel, G Stoffels… - Journal of nuclear …, 2007 - Soc Nuclear Med
In glioma of World Health Organization (WHO) grade II (low-grade glioma), the natural
course of a particular patient is not predictable and the treatment strategy is controversial …

Influence of blood-brain barrier permeability on O-(2-18F-fluoroethyl)-L-tyrosine uptake in rat gliomas

C Stegmayr, U Bandelow, D Oliveira… - European journal of …, 2017 - Springer
Abstract Purpose O-(2-18 F-fluoroethyl)-L-tyrosine (18 F-FET) is an established tracer for the
diagnosis of brain tumors with PET. This study investigates the influence of blood-brain …