Comparison of low-dose vs. high-dose CT attenuation correction for brain PET

B Bai, J Hamill, P Esser, M Slifstein, J Mann, R Parsey - 2009 - Soc Nuclear Med
1490 Objectives To compare the quantitative accuracy of PET brain scans with low dose and
clinical dose CT based attenuation corrections, phantom studies were acquired with a 64 …

Optimization of low dose CT based attenuation correction for brain PET/CT protocols

JS Kim, HS Kim, JK Ryu, WY Jung, KR Dong… - 2014 - Soc Nuclear Med
2609 Objectives Generally, in patients with nervous system diseases undergoing brain
PET/CT imaging, they also have enhanced MRI or enhanced CT so that the CT images in …

Attenuation correction optimization reduces patient dose while maintaining quantitative quality of PET/CT

W Territo, P Territo, Y Liang, G Hutchins - 2013 - Soc Nuclear Med
2629 Objectives We conducted Hoffman phantoms studies to characterize the effect of
lowering CT dose on quantification of regional brain PET. Methods A Hoffman phantom …

Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation

H Zaidi, ML Montandon, DO Slosman - European journal of nuclear …, 2004 - Springer
It is generally well accepted that transmission (TX)-based non-uniform attenuation correction
can supply more accurate absolute quantification; however, whether it provides additional …

Assessment of errors caused by x-ray scatter and use of contrast medium when using CT-based attenuation correction in PET

MR Ay, H Zaidi - European journal of nuclear medicine and molecular …, 2006 - Springer
Purpose Quantitative image reconstruction in positron emission tomography (PET) requires
an accurate attenuation map of the object under study for the purpose of attenuation …

Effect of attenuation correction on regional quantification between PET/MR and PET/CT: a multicenter study using a 3-dimensional brain phantom

J Teuho, J Johansson, J Linden… - Journal of Nuclear …, 2016 - Soc Nuclear Med
A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based
attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR …

A path to qualification of PET/MRI scanners for multicenter brain imaging studies: evaluation of MRI-based attenuation correction methods using a patient phantom

C Catana, R Laforest, H An, F Boada… - Journal of Nuclear …, 2022 - Soc Nuclear Med
PET/MRI scanners cannot be qualified in the manner adopted for hybrid PET/CT devices.
The main hurdle with qualification in PET/MRI is that attenuation correction (AC) cannot be …

Determining the Minimal Required Ultra-Low-Dose CT Dose Level for Reliable Attenuation Correction of 18F-FDG PET/CT: A Phantom Study

DW Cheng, M Ghita, D Menard… - Journal of Nuclear …, 2022 - Soc Nuclear Med
Our purpose was to investigate the minimal required submillisievert ultra-low-dose CT dose
level and the corresponding tube current and voltage for reliable attenuation correction and …

Simulation-based assessment of the impact of contrast medium on CT-based attenuation correction in PET

MR Ay, H Zaidi - 2006 IEEE Nuclear Science Symposium …, 2006 - ieeexplore.ieee.org
Although diagnostic quality CT relies on the administration of contrast agents to allow
improved lesion detectability, the misclassification of contrast medium as high density bone …

Attenuation correction with extreme CT dose reduction for whole-body FDG PET/CT

R Christopfel, D Byrd, A Alessio, E Asma, B De Man… - 2014 - Soc Nuclear Med
502 Objectives Dose reduction for PET/CT can be achieved through proper selection of CT
acquisition. If the sole purpose of the CT is for PET attenuation correction (CTAC) the CT …