Validation of an extracerebral reference region approach for the quantification of brain nicotinic acetylcholine receptors in squirrel monkeys with PET and 2-18F-fluoro …

B Le Foll, SI Chefer, AS Kimes… - Journal of Nuclear …, 2007 - Soc Nuclear Med
The aim of the present study was to explore the applicability of an extracerebral reference
region for the quantification of cerebral receptors with PET. Methods: Male squirrel monkeys …

PET imaging of α4β2* nicotinic acetylcholine receptors: quantitative analysis of 18F-nifene kinetics in the nonhuman primate

AT Hillmer, DW Wooten, MS Slesarev… - Journal of Nuclear …, 2012 - Soc Nuclear Med
The PET radioligand 2-fluoro-3-[2-((S)-3-pyrrolinyl) methoxy] pyridine (18F-nifene) is an
α4β2* nicotinic acetylcholine receptor (nAChR) agonist developed to provide accelerated in …

In vivo imaging of human cerebral nicotinic acetylcholine receptors with 2-18F-fluoro-A-85380 and PET

JD Gallezot, M Bottlaender, MC Grégoire… - Journal of Nuclear …, 2005 - Soc Nuclear Med
2-18F-Fluoro-3-[2 (S)-2-azetidinylmethoxy] pyridine (2-18F-fluoro-A-85380) is a PET
radioligand that is specific for nicotinic acetylcholine receptors (nAChRs) and has a high …

PET imaging of high-affinity α4β2 nicotinic acetylcholine receptors in humans with 18F-AZAN, a radioligand with optimal brain kinetics

DF Wong, H Kuwabara, J Kim, JR Brašić… - Journal of Nuclear …, 2013 - Soc Nuclear Med
We evaluated (−)-2-(6-[18F] fluoro-2, 3′-bipyridin-5′-yl)-7-methyl-7-aza-bicyclo [2.2. 1]
heptane (18F-AZAN), a novel radiotracer that binds to α4β2 nicotinic acetylcholine receptors …

PET imaging evaluation of [18F]DBT-10, a novel radioligand specific to α7 nicotinic acetylcholine receptors, in nonhuman primates

AT Hillmer, MQ Zheng, S Li, M Scheunemann… - European journal of …, 2016 - Springer
Purpose Positron emission tomography (PET) radioligands specific to α 7 nicotinic
acetylcholine receptors (nAChRs) afford in vivo imaging of this receptor for …

PET Imaging of nicotinic acetylcholine receptors in baboons with 18F-AZAN, a radioligand with improved brain kinetics

H Kuwabara, DF Wong, Y Gao… - Journal of Nuclear …, 2012 - Soc Nuclear Med
There are only 2 currently available radioligands, 2-18F-FA and 6-18F-FA, for quantitative
PET of the main cerebral subtype of nicotinic acetylcholine receptors (α4β2-nAChRs) in …

Quantification of nicotinic acetylcholine receptors in the human brain with PET: bolus plus infusion administration of 2-[18F] F-A85380

AS Kimes, SI Chefer, JA Matochik, CS Contoreggi… - Neuroimage, 2008 - Elsevier
Quantitative analysis of most positron emission tomography (PET) data requires arterial
blood sampling and dynamic scanning when the radioligand is administered as a bolus …

Simplified quantification of nicotinic receptors with 2 [18F] FA-85380 PET

S Mitkovski, VL Villemagne, KE Novakovic… - Nuclear medicine and …, 2005 - Elsevier
INTRODUCTION: Neuronal nicotinic acetylcholine receptors (nAChRs), widely distributed in
the human brain, are implicated in various neurophysiological processes as well as being …

Quantification of nicotinic acetylcholine receptors in human brain using [123I]5-IA-85380 SPET

M Fujita, M Ichise, CH Van Dyck, SS Zoghbi… - European journal of …, 2003 - Springer
The purpose of this study was to assess the utility of a new single-photon emission
tomography ligand,[123 I] 5-iodo-3-[2 (S)-2-azetidinylmethoxy] pyridine (5-IA-85380), to …

Imaging α4β2 Nicotinic Acetylcholine Receptors (nAChRs) in Baboons with [18F]XTRA, a Radioligand with Improved Specific Binding in Extra-Thalamic Regions

H Kuwabara, Y Gao, M Stabin, J Coughlin… - Molecular imaging and …, 2017 - Springer
Purpose Currently available positron-emitting radiotracers for imaging of the α4β2 subtype
of nicotinic acetylcholine receptors (nAChRs) exhibit high and moderate specific binding in …