Performance evaluation of the uEXPLORER total-body PET/CT scanner based on NEMA NU 2-2018 with additional tests to characterize PET scanners with a long …
BA Spencer, E Berg, JP Schmall… - Journal of Nuclear …, 2021 - Soc Nuclear Med
The world's first total-body PET scanner with an axial field of view (AFOV) of 194 cm is now
in clinical and research use at our institution. The uEXPLORER PET/CT system is the first …
in clinical and research use at our institution. The uEXPLORER PET/CT system is the first …
Performance evaluation of the Vereos PET/CT system according to the NEMA NU2-2012 standard
I Rausch, A Ruiz, I Valverde-Pascual… - Journal of Nuclear …, 2019 - Soc Nuclear Med
The aim of this study was to evaluate the physical performance of the Vereos whole-body
PET/CT system according to the National Electrical Manufacturers Association (NEMA) NU2 …
PET/CT system according to the National Electrical Manufacturers Association (NEMA) NU2 …
[HTML][HTML] Hybrid total-body pet scanners—current status and future perspectives
Purpose Since the 1990s, PET has been successfully combined with MR or CT systems. In
the past years, especially PET systems have seen a trend towards an enlarged axial field of …
the past years, especially PET systems have seen a trend towards an enlarged axial field of …
Total-body PET: maximizing sensitivity to create new opportunities for clinical research and patient care
PET is widely considered the most sensitive technique available for noninvasively studying
physiology, metabolism, and molecular pathways in the living human being. However, the …
physiology, metabolism, and molecular pathways in the living human being. However, the …
First human imaging studies with the EXPLORER total-body PET scanner
RD Badawi, H Shi, P Hu, S Chen, T Xu… - Journal of Nuclear …, 2019 - Soc Nuclear Med
Within the EXPLORER Consortium, the construction of the world's first total-body PET/CT
scanner has recently been completed. The 194-cm axial field of view of the EXPLORER …
scanner has recently been completed. The 194-cm axial field of view of the EXPLORER …
Total body PET: why, how, what for?
PET instruments are now available with a long axial field-of-view (LAFOV) to enable imaging
the total-body, or at least head and torso, simultaneously and without bed translation. This …
the total-body, or at least head and torso, simultaneously and without bed translation. This …
Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes
O Mawlawi, DA Podoloff, S Kohlmyer… - Journal of Nuclear …, 2004 - Soc Nuclear Med
This study evaluates the 2-dimensional (2D) and 3-dimensional (3D) performance
characteristics of a newly developed PET/CT scanner using the National Electrical …
characteristics of a newly developed PET/CT scanner using the National Electrical …
Simulating NEMA characteristics of the modular total-body J-PET scanner—an economic total-body PET from plastic scintillators
P Moskal, P Kowalski, RY Shopa… - Physics in Medicine …, 2021 - iopscience.iop.org
The purpose of the presented research is estimation of the performance characteristics of
the economic total-body Jagiellonian-PET system (TB-J-PET) constructed from plastic …
the economic total-body Jagiellonian-PET system (TB-J-PET) constructed from plastic …
Performance characteristics of the biograph vision quadra PET/CT system with a long axial field of view using the NEMA NU 2-2018 standard
GA Prenosil, H Sari, M Fürstner… - Journal of nuclear …, 2022 - Soc Nuclear Med
Our purpose was to evaluate the performance of the Biograph Vision Quadra PET/CT
system. This new system is based on the Biograph Vision 600, using the same silicon …
system. This new system is based on the Biograph Vision 600, using the same silicon …
PET performance measurements using the NEMA NU 2-2001 standard
ME Daube-Witherspoon, JS Karp… - Journal of Nuclear …, 2002 - Soc Nuclear Med
The NU 2-1994 standard document for PET performance measurements has recently been
updated. The updated document, NU 2-2001, includes revised measurements for spatial …
updated. The updated document, NU 2-2001, includes revised measurements for spatial …