Visual interpretation of 18F-Florbetapir PET-CT images in patients with cognitive impairment of a multicenter clinical research project-INDIA-FBP study: are the …

B Paghera, A Peli, U Guerra, D Altomare, R Giubbini - 2017 - Soc Nuclear Med
554 Objectives: to determine the intra-reader and inter-rater variability of the visual
interpratation of 18F-Florbetapir PET/CT regarding the positivity/negativity for amyloid …

Reliability, reproducibility and efficacy of the 18F florbetaben β-amyloid PET scan visual assessment method as trained via a computer-based instructional tool

J Seibyl, H Barthel, A Stephens, C Reininger, O Sabri - 2013 - Soc Nuclear Med
300 Objectives The primary objective of this study was to assess the reproducibility (inter-
and intra-reader agreement) of the visual assessment of positron emission tomography …

Comparison of visual criteria for amyloid-pet reading: could criteria merging reduce inter-rater variability?

B Paghera, D Altomare, A Peli, S Morbelli… - The Quarterly Journal …, 2019 - europepmc.org
Background Three different amyloid tracers labeled with 18-flourine have been introduced
into clinical use. The leaflets of tracers indicate different visual criteria for PET reporting. In …

[HTML][HTML] Validation of an electronic image reader training programme for interpretation of [18F] flutemetamol β-amyloid PET brain images

CJ Buckley, PF Sherwin, APL Smith… - Nuclear medicine …, 2017 - journals.lww.com
Objectives An electronic training programme (ETP) was developed for interpretation of
images during routine clinical use of the PET amyloid imaging agent [18 F] flutemetamol …

[HTML][HTML] Clinical impact of amyloid PET using 18F-florbetapir in patients with cognitive impairment and suspected Alzheimer's disease: a multicenter study

H Matsuda, K Okita, Y Motoi, T Mizuno, M Ikeda… - Annals of Nuclear …, 2022 - Springer
Objective Amyloid positron emission tomography (PET) can reliably detect senile plaques
and fluorinated ligands are approved for clinical use. However, the clinical impact of amyloid …

Initial correlative study of PET/CT brain imaging with both Amyvid and 18F-FDG in patients with cognitive impairment

S Falen, E Abella, G Arakawa - 2014 - Soc Nuclear Med
1835 Objectives To compare the results of beta amyloid plaque imaging with 18F-FDG brain
imaging in patients with cognitive impairment. Methods 36 patients with a clinical history of …

[HTML][HTML] A multisite analysis of the concordance between visual image interpretation and quantitative analysis of [18F]flutemetamol amyloid PET images

M Bucci, I Savitcheva, G Farrar, G Salvadó… - European journal of …, 2021 - Springer
Background [18 F] flutemetamol PET scanning provides information on brain amyloid load
and has been approved for routine clinical use based upon visual interpretation as either …

[HTML][HTML] Quantitation of PET signal as an adjunct to visual interpretation of florbetapir imaging

MJ Pontecorvo, AK Arora, M Devine, M Lu… - European journal of …, 2017 - Springer
Purpose This study examined the feasibility of using quantitation to augment interpretation of
florbetapir PET amyloid imaging. Methods A total of 80 physician readers were trained on …

Assessment and optimisation of hermes amyloid BRASS as a quantitative diagnostic tool in reporting 18F-florbetapir (Amyvid) investigations

N Patel, D Fakhry-Darian, K Nijran, S Khan, Z Win - 2018 - Soc Nuclear Med
1011 Purpose: Amyloid PET/CT plays an important role in investigation of patients with
cognitive impairment and dementia, especially those with atypical and mixed clinical …

How flexible is [18F] florbetaben (FBB) amyloid PET imaging regarding scan start time?

H Barthel, A Jovalekic, S Bullich, S De Santi, N Koglin… - 2017 - Soc Nuclear Med
555 Objectives:[18 F] florbetaben (FBB) is approved in the EU, the USA, Japan and South
Korea for clinical use to measure beta-amyloid plaque density in adult patients with …