The measurement of 3-o-methyldopamine in urine and plasma by a rapid and specific radioimmunoassay.

BA Faraj, VM Camp, AW Pruitt, JW Isaacs… - Journal of Nuclear …, 1977 - europepmc.org
Antiserum against 3-O-methyldopamine (MD) was produced in rabbits immunized with MD
hapten conjugated to hemocyanin. The antiserum was used to develop a …

[PDF][PDF] Development of an enzyme-radioimmunoassay for the measurement of dopamine in human plasma and urine

BA Faraj, WR Walker, VM Camp, FM Ali… - Journal of Nuclear …, 1978 - Soc Nuclear Med
MATERIALS AND METHODS Except for S-adenosylmethionine, DL-dithiothre itol, and tris
(hydroxymethyl) aminomethane, all chemicals were obtained commercially from the same …

Specific ion-exchange chromatography and fluorimetric assay for urinary 3-O-methyldopamine

Y Dalmaz, L Peyrin - Journal of Chromatography A, 1976 - Elsevier
A technique for the selective extraction of 3-O-methyldopamine, normetanephrine and
metanephrine from a single urine sample has been investigated. After hydrolysis of the …

Radioenzymatic assay of DOPA (3, 4-dihydroxyphenylalanine).

GA Johnson, JM Gren, R Kupiecki - Clinical chemistry, 1978 - academic.oup.com
We modified the single-isotope radioenzymatic assay for catecholamines [Life Sci. 21, 625
(1977)] to assay 3, 4-dihydroxyphenylalanine (DOPA). DOPA decarboxylase is used to …

Importance of urinary 3-O methyldopamine in the metabolism of adrenergic tumors

Y Dalmaz, L Peyrin - Annales D'endocrinologie, 1975 - europepmc.org
Urinary 3-O methyldopamine has been found highly increased in all cases of malignant
tumours, as well of sympathetic nature (sympathoblastoma) as of chromaffin type …

[CITATION][C] Methyldopa as an internal standard for catecholamine analysis by use of high-performance liquid chromatography.

LD Mell Jr, AB Gustafson - Clinical chemistry, 1978 - academic.oup.com
In a recent report (1) we described a chromatographic method for deter-mining free
methyldopa in human urine. The drug was absorbed onto alumina, eluted, and the eluate …

A sensitive radioenzymatic assay for dopamine, norepinephrine, and epinephrine inplasma and tissue

NBEN JONATHAN, JC PORTER - Endocrinology, 1976 - academic.oup.com
A double-isotope, radioenzymatic assayfor measuring dopamine, norepinephrine, and epi-
nephrine in one sample is described. The assayprocedure includes incubation, solvent …

Melanoma detection by enzyme-radioimmunoassay of L-dopa, dopamine, and 3-O-methyldopamine in urine.

BA Faraj, DH Lawson, DW Nixon, DR Murray… - Clinical …, 1981 - academic.oup.com
This enzyme-radioimmunoassay for the measurement of L-dopa, dopamine, and 3-O-
methyldopamine is based on the incubation of urine in the presence of catechol-O …

A simple specific radioenzymatic assay for the simultaneous measurement of picogram quantities of norepinephrine, epinephrine, and dopamine in plasma and …

MJ Sole, MN Hussain - Biochemical medicine, 1977 - Elsevier
A sensitive simple radiometric method for the simultaneous measurement of norepinephrine,
epinephrine, and dopamine is described. Fifty microliters of plasma or tissue extract was …

A reliable and simple method for simultaneous determination of dopa and 3-O-methyldopa in plasma and brain

S Fahn, ALN Prasad, R Delesie - Analytical Biochemistry, 1972 - Elsevier
A rapid, simple, and reliable method for the simultaneous estimation of D and O-MD in
plasma and brain is described. These compounds are eluted together, but separately from …