Combined carbon-13-glycine/carbon-14-octanoic acid breath test to monitor gastric emptying rates of liquids and solids.

BD Maes, YF Ghoos, BJ Geypens, G Mys… - Journal of Nuclear …, 1994 - europepmc.org
Methods A test meal was used in which the liquid phase was labeled with two markers, ie,
3.7 MBq of 111In-DTPA and 100 mg of 13C-glycine; the solid phase also was dually labeled …

Simultaneous 13 C/14 C dual isotope breath test measurement of gastric emptying of solid and liquid in normal subjects and patients: comparison with scintigraphy

CG Chew, FDL Bartholomeusz, M Bellon… - Nuclear medicine …, 2003 - journals.viamedica.pl
BACKGROUND: To develop a simple method for simultaneous solid and liquid gastric
emptying assessment using a dual isotope labelled breath test. MATERIAL AND METHODS …

Measurement of gastric emptying rate of solids by means of a carbon-labeled octanoic acid breath test

YF Ghoos, BD Maes, BJ Geypens, G Mys, MI Hiele… - Gastroenterology, 1993 - Elsevier
Background: The aim of the present study was to develop a breath test for measuring gastric
emptying rate of solids that would induce less radiation exposure than radioscintigraphy and …

[13C] octanoic acid breath test for gastric emptying of solids: accuracy, reproducibility, and comparison with scintigraphy

MG Choi, M Camilleri, DD Burton, AR Zinsmeister… - Gastroenterology, 1997 - Elsevier
BACKGROUND & AIMS: Previous work suggested that a breath test using 13C accurately
measures gastric emptying of solids. Thus, breath test half emptying time (t1/2) minus 66 …

Gastric emptying flow curves separated from carbon-labeled octanoic acid breath test results

BD Maes, G Mys, BJ Geypens… - American Journal …, 1998 - journals.physiology.org
Recently, we developed the [13/14C] octanoic acid breath test to measure gastric emptying
of solids. Although the method has been validated extensively, absorption, metabolism, and …

A valid, accurate, office based non-radioactive test for gastric emptying of solids

JS Lee, M Camilleri, AR Zinsmeister, DD Burton… - Gut, 2000 - gut.bmj.com
BACKGROUND Current breath tests for measurement of gastric emptying of solids are
expensive, possibly inaccurate, and require cumbersome calculations. AIMS We wished to …

The added diagnostic value of liquid gastric emptying compared with solid emptying alone

HA Ziessman, A Chander, JO Clarke… - Journal of Nuclear …, 2009 - Soc Nuclear Med
The medical literature states that solid gastric-emptying studies are more sensitive for the
detection of gastroparesis than are liquid studies; thus, liquid studies are rarely required …

The [13C] acetate breath test accurately reflects gastric emptying of liquids in both liquid and semisolid test meals

B Braden, S Adams, LP Duan, KH Orth, FD Maul… - Gastroenterology, 1995 - Elsevier
Background/Aims: The current standard for gastric emptying studies are radioactive isotope
methods.[13C] breath tests have been developed as a nonradioactive alternative. The aim of …

Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids

MG Choi, M Camilleri, DD Burton… - Official journal of the …, 1998 - journals.lww.com
Objective: The accuracy of the 13 C-octanoic acid breath test is enhanced by breath
sampling over 6 h rather than 4 h, but this increases the cost of the test. Our aim was to …

Measuring Gastric Emptying: Comparison of 13C-Octanoic Acid Breath Test and Scintigraphy

J Punkkinen, I Konkka, O Punkkinen… - Digestive diseases and …, 2006 - Springer
The aim of this study was to compare scintigraphy, the standard method, and the 13 C-