[PDF][PDF] Iodine-131 Treatment of Graves′ Disease Using Modified Early Iodine-131 Uptake Measurements in Therapy Dose Calculations

AA Hayes, CM Akre, CA Gorman - Journal of Nuclear Medicine, 1990 - Soc Nuclear Med
An 1311solution was prepared in the radiopharmacy for use as a tracer for routine
diagnostic thyroid uptakes. The solution was calibrated to maintain a patient dose of 2— …

Therapy dose calculation in Graves' disease using early I-123 uptake measurements

US Vemulakonda, FB Atkins… - Clinical nuclear …, 1996 - journals.lww.com
A retrospective study was performed to assess the feasibility of using the 4-hour I-123 early
uptake value in the calculation of the treatment dose of radioactive iodine in Graves' disease …

Iodine-131 uptake and turnover rate vary over short intervals in Graves' disease

JW van Isselt, JMH de Klerk… - Nuclear medicine …, 2000 - journals.lww.com
From a Dutch questionnaire, it was apparent that nearly all institutions used percentage of
radioiodine uptake for calculation of the radioiodine dose in Graves' disease. Although there …

[PDF][PDF] The radioiodine turnover rate as a determinant of radioiodine treatment outcome in Graves' disease

JW van Isselt, HS Broekhuizen-de Gast - Hell J Nucl Med, 2010 - researchgate.net
Abstract For individual iodine-131 (131I) treatment dosage calculations, most physicians use
the 'standard dosage formula', which requires measurements of thyroid volume and thyroidal …

Iodine-131 treatment of hyperthyroidism: significance of effective half-life measurements

GEB Berg, AMK Michanek… - The Journal of …, 1996 - search.proquest.com
CONCLUSION Page 1 CONCLUSION lodine-l23-B-CIT SPECT imaging in healthy humans
demonstrates low test/retest variability and good reliability across several outcome …

Thyroid Uptake of Liquid Versus Capsule 131I Tracers in Hyperthyroid Patients Treated with Liquid 131I

JN RINI, S VALLABHAJOSULA, PAT ZANZONICO… - Thyroid, 1999 - liebertpub.com
The amount of 131I used to treat hyperthyroid patients is based in part on the 24-hour
thyroid uptake of a diagnostic amount of radioiodine (tracer). We compared the 24-hour …

Four-to twenty-four-hour uptake ratio: an index of rapid iodine-131 turnover in hyperthyroidism

R Aktay, K Rezai, JE Seabold, RS Bar… - The Journal of …, 1996 - search.proquest.com
The need for parathyroid imaging in cases of persistent or Page 1 The need for parathyroid
imaging in cases of persistent or recurrent postoperative hyperparathyroidism, however, is …

Estimation of 24-hour thyroid uptake of I-131 sodium iodide using a 5-minute uptake of technetium-99m pertechnetate

JJ SMITH, BY CROFT, VA BROOKEMAN… - Clinical nuclear …, 1990 - journals.lww.com
The authors have developed a method to estimate the 24-hour sodium iodide thyroid uptake
based on a 5-minute Tc-99m pertechnetate thyroid uptake using the equation: Estimated …

Radioiodine therapy for Graves' disease: multivariate analysis of pretreatment parameters and early outcome

J Turner, W Sadler, B Brownlie, T Rogers - European Journal of Nuclear …, 1985 - Springer
Twenty-one clinical, biochemical, scan and tracerkinetic parameters were documented in 76
patients with Graves' disease who had received a standard 5-mCi therapy dose of 131 I …

Administration of additional inactive iodide during radioiodine therapy for Graves' disease

M Dietlein, D Moka, U Reinholz… - Nuklearmedizin …, 2007 - thieme-connect.com
Aim: Graves' hyperthyroidism and antithyroid drugs empty the intrathyroid stores of
hormones and iodine. The consequence is rapid 131 I turnover and impending failure of …