36-to-1 multiplexing with Prism-PET for high resolution TOF-DOI PET
38 Introduction: We've developed a multiplexing scheme that takes advantage of Prism-
PET's deterministic light sharing to enable up to 36-to-1 crystal-to-channel coupling (ie, 4 …
PET's deterministic light sharing to enable up to 36-to-1 crystal-to-channel coupling (ie, 4 …
High-resolution depth-encoding PET detector module with prismatoid light-guide array
Depth-encoding detectors with single-ended readout provide a practical, cost-effective
approach for constructing high-resolution and high-sensitivity PET scanners. However, the …
approach for constructing high-resolution and high-sensitivity PET scanners. However, the …
Performance Evaluation of the uMI Panorama PET/CT System in Accordance with the National Electrical Manufacturers Association NU 2-2018 Standard
G Li, W Ma, X Li, W Yang, Z Quan, T Ma… - Journal of Nuclear …, 2024 - Soc Nuclear Med
The uMI Panorama is a novel PET/CT system using silicon photomultiplier and application-
specific integrated circuit technologies and providing exceptional spatial and time-of-flight …
specific integrated circuit technologies and providing exceptional spatial and time-of-flight …
Towards 1mm PET resolution using DOI modules based on dual-sided SiPM readout
EP Delfino, S Majewski, RR Raylman… - IEEE Nuclear Science …, 2010 - ieeexplore.ieee.org
Parallax error in PET modules can be reduced by measuring the annihilation photon depth
of interaction (DOI) in the scintillation crystal on an event-by-event basis. Following …
of interaction (DOI) in the scintillation crystal on an event-by-event basis. Following …
Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC
M Wang, Y Wang, L Wang - Radiation Detection Technology and Methods, 2021 - Springer
Purpose We developed a low-complexity, high-resolution depth-of-interaction (DOI) capable
positron emission tomography (PET) detector and tested its performance to prove that it can …
positron emission tomography (PET) detector and tested its performance to prove that it can …
Novel staggered scintillator configurations for brain TOF-DOI PET detector
386 Objectives: Development of brain dedicated PET scanners, and other organ specific or
unconventional geometries, requires high performance detectors capable of providing high …
unconventional geometries, requires high performance detectors capable of providing high …
Scalable, time-of-flight and depth-of-interaction detector units for high-resolution pet systems
Resolving the depth of interaction (DOI) of a-photon in the scintillator is necessary to correct
for parallax errors in organ-dedicated and large-scale time-of-flight positron emission …
for parallax errors in organ-dedicated and large-scale time-of-flight positron emission …
An optimization of clinical protocol for an ultra high-resolution TOF PET/CT
B Cui, J Lu, K Shang, Z Liang, Z Deng, Y Dong - 2017 - Soc Nuclear Med
1348 Objectives: The uMI510 clinical PET/CT scanner, consisting of a 96-crytal ring LYSO
PETand a 16-slice CT tomography, is a clinical whole body PET/CTwith superb temporal …
PETand a 16-slice CT tomography, is a clinical whole body PET/CTwith superb temporal …
Virtual-pinhole PET
YC Tai, H Wu, D Pal, JA O'Sullivan - Journal of Nuclear Medicine, 2008 - Soc Nuclear Med
We proposed and tested a novel geometry for PET system design analogous to pinhole
SPECT called the virtual-pinhole PET (VP-PET) geometry to determine whether it could …
SPECT called the virtual-pinhole PET (VP-PET) geometry to determine whether it could …
Characterization of detector layers from a 1 mm3 resolution clinical PET system
PD Reynolds, FWY Lau… - 2012 IEEE Nuclear …, 2012 - ieeexplore.ieee.org
We are developing a 1 mm 3 resolution, high sensitivity PET system for breast cancer
imaging. The system comprises two 16.5 cm× 10cm× 1.8 cm detector panels each …
imaging. The system comprises two 16.5 cm× 10cm× 1.8 cm detector panels each …