Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT

A Constantinesco, P Choquet… - Journal of Nuclear …, 2005 - Soc Nuclear Med
Quantitative functional normal data should be a prerequisite before applying SPECT in
murine models of cardiac disease. Therefore, we investigated the capability of in vivo …

Reproducibility of left ventricular volume and ejection fraction measurements in rat using pinhole gated SPECT

C Vanhove, T Lahoutte, M Defrise, A Bossuyt… - European journal of …, 2005 - Springer
Purpose The aim of this study was to investigate the intra-individual reproducibility of left
ventricular volume and ejection fraction measurements in living rat using pinhole gated …

Evaluation of myocardial infarct size in rat heart by pinhole SPECT

T Hirai, R Nohara, R Hosokawa, M Tanaka… - Journal of Nuclear …, 2000 - Springer
Background High-resolution single photon emission computed tomography (SPECT) with a
pinhole collimator is a new method for evaluating the regional properties of …

Initial infarct size predicts subsequent cardiac remodeling in the rat infarct model: an in vivo serial pinhole gated SPECT study

F Maskali, PR Franken, S Poussier, N Tran… - Journal of nuclear …, 2006 - Soc Nuclear Med
The rat infarct model is widely used to study left ventricular (LV) remodeling, a main cause of
heart failure characterized by progressive LV dilatation. Using pinhole collimators and …

Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice

MC Wu, BH Hasegawa, MW Dae - Medical physics, 2002 - Wiley Online Library
The increasing use of transgenic mice as models of human physiology and disease has
motivated the development of dedicated in vivoimaging systems for anatomic and functional …

Murine cardiac images obtained with focusing pinhole SPECT are barely influenced by extra-cardiac activity

W Branderhorst, F van der Have… - Physics in Medicine …, 2012 - iopscience.iop.org
Ultra-high-resolution SPECT images can be obtained with focused multipinhole collimators.
Here we investigate the influence of unwanted high tracer uptake outside the scan volume …

Left Ventricular Functional Assessment in Mice: Feasibility of High Spatial and Temporal Resolution ECG-gated Blood Pool SPECT1

BB Chin, SD Metzler, A Lemaire, A Curcio… - Radiology, 2007 - pubs.rsna.org
Purpose: To prospectively determine feasibility of evaluating murine left ventricular (LV)
function with electrocardiographically (ECG)-gated blood pool single photon emission …

Evaluation of high-resolution pinhole SPECT using a small rotating animal

JBA Habraken, K De Bruin, M Shehata… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Ex vivo measurements in animals are used frequently in the field of nuclear medicine for the
characterization of newly developed radioligands and for drug development. In vivo SPECT …

Quantitative imaging of myocardial infarct in rats with high resolution pinhole SPECT

PD Acton, D Thomas, R Zhou - The international journal of cardiovascular …, 2006 - Springer
Small animal imaging of cardiovascular disease using single photon emission tomography
(SPECT) can be used to provide quantitative measurements of myocardial infarct. The …

Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging

A Abidov, G Germano, R Hachamovitch… - Journal of Nuclear …, 2006 - Elsevier
Conclusion We have reviewed the development of assessments of ventricular function by
use of gated MPS and the ways in which these measurements have contributed to the …