Standardized uptake value (SUVmax) in 18F-FDG PET/CT is correlated with the total number of main oncogenic anomalies in cancer patients

A Haghighat Jahromi, G Chang… - Cancer Biology & …, 2020 - Taylor & Francis
Cancer diagnosis and therapy is quickly moving from the traditional histology-based
approaches to genomic stratification, providing a huge opportunity for radiogenomics …

[HTML][HTML] TP53 mutations and number of alterations correlate with maximum standardized uptake value (SUVmax) determined by positron emission tomography …

GH Chang, R Kurzrock, L Tran, M Schwaederle… - Oncotarget, 2018 - ncbi.nlm.nih.gov
Background Our study explored the relationship between the molecular changes in cancer
and the maximum standardized uptake value (SUVmax) determined by positron emission …

[HTML][HTML] SUVmax of 2.5 should not be embraced as a magic threshold for separating benign from malignant lesions

TC Kwee, G Cheng, MGEH Lam, S Basu… - European journal of …, 2013 - Springer
Lesions of an indeterminate nature are often encountered in images such as those from CT
and MRI. Examples include solitary pulmonary nodules and various incidentalomas that …

[HTML][HTML] Relationship between tumor mutational burden and maximum standardized uptake value in 2-[18F]FDG PET (positron emission tomography) scan in cancer …

A Haghighat Jahromi, DA Barkauskas, M Zabel… - EJNMMI research, 2020 - Springer
Purpose Deriving links between imaging and genomic markers is an evolving field. 2-[18 F]
FDG PET/CT (18 F-fluorodeoxyglucose positron emission tomography–computed …

Genetic alterations in colorectal cancer have different patterns on 18F-FDG PET/CT

SW Chen, CY Lin, CM Ho, YS Chang… - Clinical nuclear …, 2015 - journals.lww.com
Purpose The aim of this study was to understand the association between various genetic
mutation and 18 F-FDG PET-related parameters in patients with colorectal cancer (CRC) …

F18-FDG-PET/CT standardised uptake value threshold in discriminating benign vs. malignant lesions. Doubts and certainties in the era of evidence-based medicine

F Bertagna, R Giubbini - Acta Oncologica, 2012 - Taylor & Francis
Department of Nuclear Medicine, University of Brescia and Spedali Civili di Brescia, Brescia,
Italy to the editor, an interesting article has recently been published on acta oncologica [1] …

Suboptimal and inadequate quantification: an alarming crisis in medical applications of PET

S Basu, TC Kwee, D Torigian, B Saboury… - European journal of …, 2011 - Springer
Dear Sir, In addition to its remarkable capability for unraveling the underlying molecular
characteristics of a multitude of disorders with unprecedented sensitivity, positron emission …

FDG-PET-based differential uptake volume histograms: a possible approach towards definition of biological target volumes

S Devic, H Mohammed, N Tomic… - The British Journal of …, 2016 - academic.oup.com
Objective: Integration of fluorine-18 fludeoxyglucose (18F-FDG)-positron emission
tomography (PET) functional data into conventional anatomically based gross tumour …

[HTML][HTML] An investigation of the relation between tumor-to-liver ratio (TLR) and tumor-to-blood standard uptake ratio (SUR) in oncological FDG PET

F Hofheinz, R Bütof, I Apostolova, K Zöphel, IG Steffen… - EJNMMI research, 2016 - Springer
Background The standardized uptake value (SUV) is the nearly exclusive means for
quantitative evaluation of clinical [18F-] fluorodeoxyglucose (18F-FDG) positron emission …

Promising Candidate Prognostic Biomarkers in [18F] FDG PET Images: Evaluation in Independent Cohorts of Non–Small Cell Lung Cancer Patients

N Hovhannisyan-Baghdasarian… - Journal of Nuclear …, 2024 - Soc Nuclear Med
The normalized distances from the hot spot of radiotracer uptake (SUVmax) to the tumor
centroid (NHOC) and to the tumor perimeter (NHOP) have recently been suggested as novel …