[PDF][PDF] Bone scintigraphy—comparison of 99mTc-polyphosphate and 99mTc-diphosphonate
AN Serafini, DD Watson, JP Nelson… - Journal of Nuclear …, 1974 - Soc Nuclear Med
Ierencesin the bonescansweredemonstrated. Page 1 Eighteen patients were randomly
adminis tered either PPmTc.diphosphonate or 9smTc.poly. phosphate and then reatudied …
adminis tered either PPmTc.diphosphonate or 9smTc.poly. phosphate and then reatudied …
A computer assisted comparison of 99TCm-methylene-diphosphonate and 99TCm-pyrophosphate bone imaging
U Büll, JP Pfeifer, HP Niendorf… - The British Journal of …, 1977 - academic.oup.com
A total of 350 patient studies were carried out using clinical trials' batches of the Technetium
(MDP) agent for bone scintigraphy (The Radiochemical Centre), and a commercially …
(MDP) agent for bone scintigraphy (The Radiochemical Centre), and a commercially …
[PDF][PDF] Clinical comparison of the kinetics of 99mTc-labeled polyphosphate and diphosphonate
GT Krishnamurthy, M Tubis, JS Endow… - Journal of Nuclear …, 1974 - Soc Nuclear Med
MATERIALS AND METHODS Ten patients with suspected bone lesions were stud ied. The
nature of the study was explained and writ ten informed consent was obtained from each …
nature of the study was explained and writ ten informed consent was obtained from each …
[PDF][PDF] Optimization of the ratio of stannous tin: ethane-1-hydroxy-1, 1-diphosphonate for bone scanning with 99mTc-pertechnetate
AJ Tofe, MD Francis - Journal of Nuclear Medicine, 1974 - Soc Nuclear Med
MATERIALS AND METHODS The components of the skeletal scanning agent are EHDP,
stannous chloride, and oomTc@ pertechnetate (OnmTcO-). The 1-†4C-EHDP was …
stannous chloride, and oomTc@ pertechnetate (OnmTcO-). The 1-†4C-EHDP was …
Comparison of 99mTc-labeled phosphate and phosphonate agents for skeletal imaging
MA Davis, AG Jones - Seminars in nuclear medicine, 1976 - Elsevier
The use of 99m Tc-labeled phosphate and phosphonate compounds in place of 18 F, 85 Sr,
and 87m Sr for bone scintigraphy has become commonplace throughout the world in a …
and 87m Sr for bone scintigraphy has become commonplace throughout the world in a …
[PDF][PDF] Technetium-99m-labeled stannous imidodiphosphate, a new radiodiagnostic agent for bone scanning: comparison with other 99mTc complexes
G Subramanian, JG McAfee, RJ Blair… - Journal of Nuclear …, 1975 - Soc Nuclear Med
85Sras a reference standard. The SSmTc-IDPcon centrated 20% higher in the bone, and its
softtissue and blood levels were lower than with S5Sr. By comparison, the concentrations in …
softtissue and blood levels were lower than with S5Sr. By comparison, the concentrations in …
[CITATION][C] RADIOCHEMICAL EVALUATION AND IMAGE CORRELATION OF STABILIZED AND NONSTABILIZED 99mTc-Sn-DIPHOSPHONATE KITS
AM Zimmer, DG Pavel - Journal of Nuclear Medicine Technology, 1977 - Soc Nuclear Med
In the December 1976 issue of the Journal of Nuclear Medicine Technology, McCormick,
Sinclair, and Wahner have reported on the chromatographic quality and clinical correlation …
Sinclair, and Wahner have reported on the chromatographic quality and clinical correlation …
[PDF][PDF] Effects of radiation therapy on bone lesions as measured by 99mTc-diphosphonate
FP Castronovo, MS Potsaid… - Journal of Nuclear …, 1973 - Soc Nuclear Med
MATERIALS AND METHODS Our initial study was carried out in an adult white man (MGH#
1670755) who had a bony metastases from an adenocarcinoma of the lung to the spine and …
1670755) who had a bony metastases from an adenocarcinoma of the lung to the spine and …
Clinical experience with a new bone seeking 99sup(m)Tc radiopharmaceutical
TI Hale, A Jucker, K Vgenopoulos, B Sauter… - … , Compact News in …, 1981 - inis.iaea.org
[en] The new bone seeker, 99 sup (m) Tc-2, 3 dicarboxypropane-1, 1-diphosphonate (Tc-
DPD) was compared with 99 sup (m) Tc methylene diphosphonate (Tc-MDP) by use of thin …
DPD) was compared with 99 sup (m) Tc methylene diphosphonate (Tc-MDP) by use of thin …
Clinical comparison of technetium-99m diphosphonate and pyrophosphate in bone scintigraphy: concise communication.
EB Silberstein, HR Maxon 3rd… - Journal of Nuclear …, 1978 - europepmc.org
Thirty patients had bone scintigraphy with both Tc-99m pyrophosphate (Tc-PPi) and Tc-99m
diphosphonate (Tc-HEDP). The images were given a composite rating for quality and the …
diphosphonate (Tc-HEDP). The images were given a composite rating for quality and the …
Related searches
- bone scintigraphy 99mtc polyphosphate
- bone lesions 99mtc diphosphonate
- bone scintigraphy clinical comparison
- bone scintigraphy concise communication
- bone scintigraphy technetium 99m
- radiation therapy 99mtc diphosphonate
- bone scanning 99mtc complexes
- methylene diphosphonate bone imaging
- bone scintigraphy 99mtc diphosphonate