[CITATION][C] When magic bullets ricochet

AJ Fischman - Journal of Nuclear Medicine, 1990 - Soc Nuclear Med
are obtained. Demonstrating the presence of antigen in a lesion for which a diagnostic
image was obtained, though necessary, is not sufficient evidence to reach this conclusion …

Indium-111-antimyosin images compared with triphenyl tetrazolium chloride staining in a patient six days after myocardial infarction.

D Jain, JC Crawley, A Lahiri… - Journal of Nuclear …, 1990 - europepmc.org
The results of indium-111 (111In) antimyosin imaging during life and the findings on
postmortem imaging and triphenyl tetrazolium chloride (TTC) staining of the heart are …

Antimyosin imaging in cardiac transplant rejection.

LL Johnson, PJ Cannon - Circulation, 1991 - europepmc.org
Fab fragments of antibodies specific for cardiac myosin have been labeled with indium-111
and injected intravenously into animals and into patients with heart transplants. The …

The role of antimyosin antibodies in acute myocardial infarction

LL Johnson, DW Seldin - Seminars in nuclear medicine, 1989 - Elsevier
Antimyosin is an Fab fragment of a monoclonal antibody that binds with human myosin
exposed in myocytes irreversibly damaged by an ischemic event. Labeled with 111 In, the …

Diagnostic accuracy of antimyosin scintigraphy in suspected myocarditis

J Narula, BA Khaw, GW Dec, IF Palacios… - Journal of Nuclear …, 1996 - Elsevier
Background. Radiolabeled antibody specific for cardiac myosin administered intravenously
has been used to define noninvasively regions of myocardial necrosis. Inflammatory heart …

99mTc-antimyosin antibody imaging for the detection of acute myocardial infarction in human beings

R Senior, S Bhattacharya, P Manspeaker, XJ Liu… - American Heart …, 1993 - Elsevier
Abstract 111 In-antimyosin imaging is a highly sensitive and specific technique for the
detection of myocardial necrosis. Two new methods of labeling antimyosin with 99m Tc have …

Indium-111 antimyosin scintigraphy to assess myocardial damage in patients with suspected myocarditis and cardiac rejection.

I Carrió, L Berná, M Ballester, M Estorch… - Journal of Nuclear …, 1988 - europepmc.org
Indium-111 antimyosin scans were used to assess myocardial damage in patients with
suspected myocarditis and cardiac transplant rejection. The calculation of a myocardium to …

Clinical trial of 111In-antimyosin antibody imaging:(3) Comparison with 99mTc-pyrophosphate imaging

N Tamaki, T Yamada, A Matsumori, T Fujita… - Kaku igaku. The …, 1989 - europepmc.org
Clinical value of 111In-antimyosin monoclonal antibody F ab (AM) was compared with
99mTc-pyrophosphate (PYP) in 13 patients with myocardial infarction and 3 patients with …

Monoclonal Fab antimyosin in cardiac imaging

LL Johnson - Clinical cardiology, 1992 - Wiley Online Library
Antimyosin is an Fab fragment of a murine monoclonal antibody directed against human
heavy chain myosin. It is specific for myocyte necrosis. When linked via …

Myocardial uptake of antimyosin monoclonal antibody in a murine model of viral myocarditis.

A Matsumori, T Ohkusa, Y Matoba, I Okada, T Yamada… - Circulation, 1989 - Am Heart Assoc
The myocardial uptake of 125I-and 131I-antimyosin monoclonal antibody Fab in
experimental myocarditis in BALB/c mice induced by encephalomyocarditis virus was …