[PDF][PDF] FDG-PET in oncology: there's more to it than looking at pictures
AJ Fischman, NM Alpert - Journal of Nuclear Medicine, 1993 - Soc Nuclear Med
When plateau concentrations of FDG are achieved in tissues with low con centration of
glucose-6-phosphatase, images oftotal †8Fradioactivity reflect relative rates of glycolysis …
glucose-6-phosphatase, images oftotal †8Fradioactivity reflect relative rates of glycolysis …
[CITATION][C] Quantitating tumor glucose metabolism with FDG and PET
The rate constants K* 1and k* 2refer to forward and reverse capillary trans port of FDG, while
k* 3 and k* 4 refer to phosphorylation of FDG and de phosphorylation of FDG-6-P04, re …
k* 3 and k* 4 refer to phosphorylation of FDG and de phosphorylation of FDG-6-P04, re …
The rate-limiting step for tumor [18F] fluoro-2-deoxy-D-glucose (FDG) incorporation
TAD Smith - Nuclear medicine and biology, 2001 - Elsevier
The enhanced rate of glucose utilization by tumor cells has been exploited in the imaging of
tumors using the radiolabelled glucose analogue fluoro-2-deoxy-D-glucose (FDG)[1], which …
tumors using the radiolabelled glucose analogue fluoro-2-deoxy-D-glucose (FDG)[1], which …
[PDF][PDF] Simplified measurement of deoxyglucose utilization rate
GJ Hunter, LM Hamberg, NM Alpert… - Journal of Nuclear …, 1996 - Soc Nuclear Med
Conclusion: These results indicate that the observed tumor tissue uptake of 18FDG,
corrected for blood 18FDGactivity and glucose concentration, can reliably predict glucose …
corrected for blood 18FDGactivity and glucose concentration, can reliably predict glucose …
Quantitative assessment of tumor metabolism using FDG-PET imaging
Positron emission tomography using the glucose analog fluorine-18 fluorodeoxyglucose
(FDG-PET) provides a unique means of non-invasive assessment of tumor metabolism …
(FDG-PET) provides a unique means of non-invasive assessment of tumor metabolism …
Pitfalls in oncologic diagnosis with FDG PET imaging: physiologic and benign variants
A rapidly emerging clinical application of positron emission tomography (PET) is the
detection and staging of cancer with the glucose analogue tracer 2-[fluorine-18] fluoro-2 …
detection and staging of cancer with the glucose analogue tracer 2-[fluorine-18] fluoro-2 …
[HTML][HTML] FDG-PET and PET/CT-Part II
AM Takalkar, G El-Haddad, DL Lilien - The Indian journal of …, 2008 - ncbi.nlm.nih.gov
The high diagnostic accuracy of FDG-PET and PET/CT has been well documented for
several neoplasms, with a consequent rapid increase in the utilization and acceptance of …
several neoplasms, with a consequent rapid increase in the utilization and acceptance of …
[PDF][PDF] Influence of the blood glucose concentration on FDG uptake in cancer—a PET study
P Lindholm, H Minn, S Leskinen-Kallio… - Journal of nuclear …, 1993 - Soc Nuclear Med
99.0% ±0.4% andthespecificactivityabout2 Ci/@ imolatthe end ofthe synthesis. The first
PET-FDG study was performed in the fasting state. After fastingovernight, the patients …
PET-FDG study was performed in the fasting state. After fastingovernight, the patients …
GLUT1 expression in tissue and 18F-FDG uptake
N Avril - Journal of Nuclear Medicine, 2004 - Soc Nuclear Med
FDG PET imaging has been applied for about a decade. It is generally accepted that
imaging the metabolic activity of tumor tissue provides more sensitive and more specific …
imaging the metabolic activity of tumor tissue provides more sensitive and more specific …
FDG uptake, tumour characteristics and response to therapy: a review
TAD Smith - Nuclear medicine communications, 1998 - journals.lww.com
The use of FDG-PET imaging in tumour detection is now well established. Many studies
have suggested that changes in the uptake of FDG predict tumour response to therapy and …
have suggested that changes in the uptake of FDG predict tumour response to therapy and …