[PDF][PDF] FDG-PET in oncology: there's more to it than looking at pictures

AJ Fischman, NM Alpert - Journal of Nuclear Medicine, 1993 - Soc Nuclear Med
When plateau concentrations of FDG are achieved in tissues with low con centration of
glucose-6-phosphatase, images oftotal †8Fradioactivity reflect relative rates of glycolysis …

[CITATION][C] Quantitating tumor glucose metabolism with FDG and PET

RA Hawkins, Y Choi, SC Huang, C Messa… - Journal of Nuclear …, 1992 - Soc Nuclear Med
The rate constants K* 1and k* 2refer to forward and reverse capillary trans port of FDG, while
k* 3 and k* 4 refer to phosphorylation of FDG and de phosphorylation of FDG-6-P04, re …

The rate-limiting step for tumor [18F] fluoro-2-deoxy-D-glucose (FDG) incorporation

TAD Smith - Nuclear medicine and biology, 2001 - Elsevier
The enhanced rate of glucose utilization by tumor cells has been exploited in the imaging of
tumors using the radiolabelled glucose analogue fluoro-2-deoxy-D-glucose (FDG)[1], which …

[PDF][PDF] Simplified measurement of deoxyglucose utilization rate

GJ Hunter, LM Hamberg, NM Alpert… - Journal of Nuclear …, 1996 - Soc Nuclear Med
Conclusion: These results indicate that the observed tumor tissue uptake of 18FDG,
corrected for blood 18FDGactivity and glucose concentration, can reliably predict glucose …

Quantitative assessment of tumor metabolism using FDG-PET imaging

WA Weber, M Schwaiger, N Avril - Nuclear medicine and biology, 2000 - Elsevier
Positron emission tomography using the glucose analog fluorine-18 fluorodeoxyglucose
(FDG-PET) provides a unique means of non-invasive assessment of tumor metabolism …

Pitfalls in oncologic diagnosis with FDG PET imaging: physiologic and benign variants

PD Shreve, Y Anzai, RL Wahl - Radiographics, 1999 - pubs.rsna.org
A rapidly emerging clinical application of positron emission tomography (PET) is the
detection and staging of cancer with the glucose analogue tracer 2-[fluorine-18] fluoro-2 …

[HTML][HTML] FDG-PET and PET/CT-Part II

AM Takalkar, G El-Haddad, DL Lilien - The Indian journal of …, 2008 - ncbi.nlm.nih.gov
The high diagnostic accuracy of FDG-PET and PET/CT has been well documented for
several neoplasms, with a consequent rapid increase in the utilization and acceptance of …

[PDF][PDF] Influence of the blood glucose concentration on FDG uptake in cancer—a PET study

P Lindholm, H Minn, S Leskinen-Kallio… - Journal of nuclear …, 1993 - Soc Nuclear Med
99.0% ±0.4% andthespecificactivityabout2 Ci/@ imolatthe end ofthe synthesis. The first
PET-FDG study was performed in the fasting state. After fastingovernight, the patients …

GLUT1 expression in tissue and 18F-FDG uptake

N Avril - Journal of Nuclear Medicine, 2004 - Soc Nuclear Med
FDG PET imaging has been applied for about a decade. It is generally accepted that
imaging the metabolic activity of tumor tissue provides more sensitive and more specific …

FDG uptake, tumour characteristics and response to therapy: a review

TAD Smith - Nuclear medicine communications, 1998 - journals.lww.com
The use of FDG-PET imaging in tumour detection is now well established. Many studies
have suggested that changes in the uptake of FDG predict tumour response to therapy and …