A review of deep-learning-based approaches for attenuation correction in positron emission tomography

JS Lee - IEEE Transactions on Radiation and Plasma Medical …, 2020 - ieeexplore.ieee.org
Attenuation correction (AC) is essential for the generation of artifact-free and quantitatively
accurate positron emission tomography (PET) images. PET AC based on computed …

Attenuation correction for human PET/MRI studies

C Catana - Physics in Medicine & Biology, 2020 - iopscience.iop.org
Attenuation correction has been one of the main methodological challenges in the
integrated positron emission tomography and magnetic resonance imaging (PET/MRI) field …

[HTML][HTML] A multi-centre evaluation of eleven clinically feasible brain PET/MRI attenuation correction techniques using a large cohort of patients

CN Ladefoged, I Law, U Anazodo, KS Lawrence… - Neuroimage, 2017 - Elsevier
Aim To accurately quantify the radioactivity concentration measured by PET, emission data
need to be corrected for photon attenuation; however, the MRI signal cannot easily be …

Clinical evaluation of zero-echo-time attenuation correction for brain 18F-FDG PET/MRI: comparison with atlas attenuation correction

T Sekine, EEGW Ter Voert, G Warnock… - Journal of Nuclear …, 2016 - Soc Nuclear Med
Accurate attenuation correction (AC) on PET/MR is still challenging. The purpose of this
study was to evaluate the clinical feasibility of AC based on fast zero-echo-time (ZTE) MRI by …

Reduction of 18F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier Detectors

T Sekine, G Delso, KG Zeimpekis, F de Galiza Barbosa… - Radiology, 2018 - pubs.rsna.org
Purpose To determine the level of clinically acceptable reduction in injected fluorine 18
(18F) fluorodeoxyglucose (FDG) dose in time-of-flight (TOF)–positron emission tomography …

[HTML][HTML] Regional Accuracy of ZTE-Based Attenuation Correction in Static [18F]FDG and Dynamic [18F]PE2I Brain PET/MR

G Schramm, M Koole, SMA Willekens, A Rezaei… - Frontiers in …, 2019 - frontiersin.org
Accurate MR-based attenuation correction (MRAC) is essential for quantitative PET/MR
imaging of the brain. In this study, we analyze the regional bias caused by MRAC based on …

[HTML][HTML] Magnetic resonance-based attenuation correction and scatter correction in neurological positron emission tomography/magnetic resonance imaging—current …

J Teuho, A Torrado-Carvajal, H Herzog… - Frontiers in …, 2020 - frontiersin.org
In this review, we will summarize the past and current state-of-the-art developments in
attenuation and scatter correction approaches for hybrid positron emission tomography …

Subject-specific bone attenuation correction for brain PET/MR: can ZTE-MRI substitute CT scan accurately?

M Khalifé, B Fernandez, O Jaubert… - Physics in Medicine …, 2017 - iopscience.iop.org
In brain PET/MR applications, accurate attenuation maps are required for accurate PET
image quantification. An implemented attenuation correction (AC) method for brain imaging …

PET/MR outperforms PET/CT in suspected occult tumors

T Sekine, F de Galiza Barbosa, BR Sah… - Clinical nuclear …, 2017 - journals.lww.com
Background To compare the diagnostic accuracy of PET/MR and PET/CT in patients with
suspected occult primary tumors. Methods This prospective study was approved by the …

Innate immune cells and myelin profile in multiple sclerosis: a multi-tracer PET/MR study

MS Pitombeira, M Koole, KR Campanholo… - European Journal of …, 2022 - Springer
Purpose Neuropathological studies have demonstrated distinct profiles of microglia
activation and myelin injury among different multiple sclerosis (MS) phenotypes and …