Evolving Role of Molecular Imaging with 18F-Sodium Fluoride PET as a Biomarker for Calcium Metabolism

W Raynor, S Houshmand, S Gholami… - Current osteoporosis …, 2016 - Springer
Abstract 18 F-sodium fluoride (NaF) as an imaging tracer portrays calcium metabolic activity
either in the osseous structures or in soft tissue. Currently, clinical use of NaF-PET is …

Amyloid PET as a marker of normal-appearing white matter early damage in multiple sclerosis: correlation with CSF β-amyloid levels and brain volumes

AM Pietroboni, T Carandini, A Colombi… - European Journal of …, 2019 - Springer
Purpose The disease course of multiple sclerosis (MS) is unpredictable, and reliable
prognostic biomarkers are needed. Positron emission tomography (PET) with β-amyloid …

[HTML][HTML] Optimization of a Bayesian penalized likelihood algorithm (Q.Clear) for 18F-NaF bone PET/CT images acquired over shorter durations using a custom …

T Yoshii, K Miwa, M Yamaguchi, K Shimada… - EJNMMI physics, 2020 - Springer
Abstract Background The Bayesian penalized likelihood (BPL) algorithm Q. Clear (GE
Healthcare) allows fully convergent iterative reconstruction that results in better image …

Partial volume correction for improved PET quantification in 18F-NaF imaging of atherosclerotic plaques

J Cal-Gonzalez, X Li, D Heber, I Rausch… - Journal of Nuclear …, 2018 - Elsevier
Background Accurate quantification of plaque imaging using 18 F-NaF PET requires partial
volume correction (PVC). Methods PVC of PET data was implemented by the use of a local …

Multimodal partial volume correction: Application to [11C]PIB PET/MRI myelin imaging in multiple sclerosis

E Grecchi, M Veronese, B Bodini… - Journal of Cerebral …, 2017 - journals.sagepub.com
The [11C] PIB PET tracer, originally developed for amyloid imaging, has been recently
repurposed to quantify demyelination and remyelination in multiple sclerosis (MS). Myelin …

[HTML][HTML] Error propagation analysis of seven partial volume correction algorithms for [18F]THK-5351 brain PET imaging

S Oyama, A Hosoi, M Ibaraki, CJ McGinnity… - EJNMMI physics, 2020 - Springer
Background Novel partial volume correction (PVC) algorithms have been validated by
assuming ideal conditions of image processing; however, in real clinical PET studies, the …

Optimization of yttrium‐90 PET for simultaneous PET/MR imaging: A phantom study

M Eldib, N Oesingmann, DD Faul… - Medical …, 2016 - Wiley Online Library
Purpose: Positron emission tomography (PET) imaging of yttrium‐90 in the liver post
radioembolization has been shown useful for personalized dosimetry calculations and …

Iterative structural and functional synergistic resolution recovery (iSFS-RR) applied to PET-MR images in epilepsy

J Silva-Rodriguez, J Cortés… - … on Nuclear Science, 2016 - ieeexplore.ieee.org
Structural Functional Synergistic Resolution Recovery (SFS-RR) is a technique that uses
supplementary structural information from MR or CT to improve the spatial resolution of PET …

Post-reconstruction-based partial volume correction methods: a comprehensive review

H Jomaa, R Mabrouk, N Khlifa - Biomedical Signal Processing and Control, 2018 - Elsevier
The vital role of positron emission tomography (PET) image is to provide an accurate
quantitative information. Nevertheless, the partial volume effect (PVE) can easily alter the …

[PDF][PDF] Amyloid PET as a marker of normal-appearing white matter early damage in multiple sclerosis: correlation with CSF ß-amyloid levels and brain volumes

AM Pietroboni, T Carandini, A Colombi, M Mercurio… - sussex.figshare.com
Purpose: The disease course of multiple sclerosis (MS) is unpredictable and reliable
prognostic biomarkers are needed. Positron emission tomography (PET) with β-amyloid …