[HTML][HTML] Performance evaluation of the next generation solid-state digital photon counting PET/CT system
Background The first solid-state silicon photomultiplier (SiPM) digital photon counting (DPC)
clinical PET/CT system was introduced by Philips in recent years. The system differs from …
clinical PET/CT system was introduced by Philips in recent years. The system differs from …
[HTML][HTML] The spatial extent of tauopathy on [18F] MK-6240 tau PET shows stronger association with cognitive performances than the standard uptake value ratio in …
T Gérard, L Colmant, V Malotaux, Y Salman… - European Journal of …, 2024 - Springer
Purpose [18 F] MK-6240, a second-generation tau PET tracer, is increasingly used for the
detection and the quantification of in vivo cerebral tauopathy in Alzheimer's disease (AD) …
detection and the quantification of in vivo cerebral tauopathy in Alzheimer's disease (AD) …
Cardiac atrial metabolism quantitative assessment with analog and digital time of flight-PET/computed tomography
M Hesse, S Marchandise, B Gerber… - Nuclear medicine …, 2023 - journals.lww.com
Background Evaluation of left atrium (LA) remodeling is becoming increasingly relevant in
understanding several pathological cardiac conditions. 18 F-FDG-PET/computed …
understanding several pathological cardiac conditions. 18 F-FDG-PET/computed …
Validation of phantom‐based harmonization for patient harmonization
JV Panetta, ME Daube‐Witherspoon… - Medical physics, 2017 - Wiley Online Library
Purpose To improve the precision of multicenter clinical trials, several efforts are underway
to determine scanner‐specific parameters for harmonization using standardized phantom …
to determine scanner‐specific parameters for harmonization using standardized phantom …
Solid-State Digital Photon Counting PET/CT
J Zhang, MV Knopp - Advances in PET: The Latest in Instrumentation …, 2020 - Springer
In this chapter, we describe the solid-state digital photon counting (DPC) clinical PET/CT,
Vereos TF 64, a system differing from other SiPM-based PET/CT systems by directly …
Vereos TF 64, a system differing from other SiPM-based PET/CT systems by directly …
Image-based point-spread-function modelling in time-of-flight positron-emission-tomography iterative list-mode reconstruction
J Qi, J Zhou, YE Hongwei, W Wang - US Patent 10,216,701, 2019 - Google Patents
A method of calculating a system matrix for time-of-flight (TOF) list-mode reconstruction of
positron-emission tomography (PET) images, the method including determining a TOF …
positron-emission tomography (PET) images, the method including determining a TOF …
Cardiac atrial metabolism quantitative assessment with analog and digital TOF-PET/CT
M Hesse, S Marchandise, B Gerber, V Roelants - 2022 - researchsquare.com
Background: Evaluation of left atrial (LA) remodeling is becoming increasingly relevant in
understanding several pathological cardiac conditions. While 18 F-FDG-PET/CT is currently …
understanding several pathological cardiac conditions. While 18 F-FDG-PET/CT is currently …
Deconvolution based attenuation correction for time-of-flight positron emission tomography
NY Lee - Journal of the Korean Physical Society, 2017 - Springer
For an accurate quantitative reconstruction of the radioactive tracer distribution in positron
emission tomography (PET), we need to take into account the attenuation of the photons by …
emission tomography (PET), we need to take into account the attenuation of the photons by …
[BOOK][B] Development of a Scintillation Detector and the Influence on Clinical Imaging
JV Panetta - 2017 - search.proquest.com
The detector is the functional unit within a Positron Emission Tomography (PET) scanner,
serving to convert the energy of radiation emitted from a patient into positional information …
serving to convert the energy of radiation emitted from a patient into positional information …