[HTML][HTML] FDG-PET imaging in mild traumatic brain injury: a critical review

KR Byrnes, CM Wilson, F Brabazon… - Frontiers in …, 2014 - frontiersin.org
Traumatic brain injury (TBI) affects an estimated 1.7 million people in the United States and
is a contributing factor to one third of all injury related deaths annually. According to the …

Small-animal positron emission tomography as a tool for neuropharmacology

S Lancelot, L Zimmer - Trends in pharmacological sciences, 2010 - cell.com
Small-animal positron emission tomography (PET) is a preclinical imaging method that uses
pharmacologically or biochemically active compounds labelled with short-lived positron …

Increased regional cerebral glucose uptake in an APP/PS1 model of Alzheimer's disease

G Poisnel, AS Hérard, NET El Tayara, E Bourrin… - Neurobiology of …, 2012 - Elsevier
Alzheimer's disease (AD), the most common age-related neurodegenerative disorder, is
characterized by the invariant cerebral accumulation of β-amyloid peptide. This event occurs …

[HTML][HTML] Combined [18F]DPA-714 micro-positron emission tomography and autoradiography imaging of microglia activation after closed head injury in mice

I Israel, A Ohsiek, E Al-Momani… - Journal of …, 2016 - Springer
Background Traumatic brain injury (TBI) is a major cause of death and disability.
Neuroinflammation contributes to acute damage after TBI and modulates long-term …

Image-derived input function from the vena cava for 18F-FDG PET studies in rats and mice

B Lanz, C Poitry-Yamate, R Gruetter - Journal of Nuclear Medicine, 2014 - Soc Nuclear Med
Measurement of arterial input function is a restrictive aspect for quantitative 18F-FDG PET
studies in rodents because of their small total blood volume and the related difficulties in …

[HTML][HTML] Evodiamine improves congnitive abilities in SAMP8 and APPswe/PS1ΔE9 transgenic mouse models of Alzheimer's disease

S Yuan, K Gao, D Wang, X Quan, J Liu, C Ma… - Acta Pharmacologica …, 2011 - nature.com
Aim: To investigate the effect of evodiamine (a quinolone alkaloid from the fruit of Evodia
rutaecarpa) on the progression of Alzheimer's disease in SAMP8 and APP swe/PS1 ΔE9 …

An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data

G Wang, J Qi - IEEE transactions on medical imaging, 2012 - ieeexplore.ieee.org
Direct reconstruction of kinetic parameters from raw projection data is a challenging task in
molecular imaging using dynamic positron emission tomography (PET). This paper presents …

[HTML][HTML] Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner

MC Huisman, LW van Golen, NJ Hoetjes, HN Greuter… - EJNMMI research, 2012 - Springer
Background Positron emission tomography (PET) allows for the measurement of cerebral
blood flow (CBF; based on [15 O] H 2 O) and cerebral metabolic rate of glucose utilization …

Simplified protocol for whole‐body Patlak parametric imaging with 18F‐FDG PET/CT: Feasibility and error analysis

S Yao, T Feng, Y Zhao, R Wu, R Wang, S Wu… - Medical …, 2021 - Wiley Online Library
Purpose Parametric imaging using the Patlak model has been shown to provide improved
lesion detectability and specificity. The Patlak model requires both tissue time–activity …

Quantification of brain glucose metabolism by 18F-FDG PET with real-time arterial and image-derived input function in mice

MF Alf, MT Wyss, A Buck, B Weber… - Journal of Nuclear …, 2013 - Soc Nuclear Med
Kinetic modeling of PET data derived from mouse models remains hampered by the