Neuroimaging of epilepsy
Imaging is pivotal in the evaluation and management of patients with seizure disorders.
Elegant structural neuroimaging with magnetic resonance imaging (MRI) may assist in …
Elegant structural neuroimaging with magnetic resonance imaging (MRI) may assist in …
[HTML][HTML] PET studies in epilepsy
I Sarikaya - American journal of nuclear medicine and molecular …, 2015 - ncbi.nlm.nih.gov
Various PET studies, such as measurements of glucose, serotonin and oxygen metabolism,
cerebral blood flow and receptor bindings are availabe for epilepsy. 18 Fluoro-2 …
cerebral blood flow and receptor bindings are availabe for epilepsy. 18 Fluoro-2 …
Surgical outcome and prognostic factors of frontal lobe epilepsy surgery
Frontal lobe epilepsy (FLE) surgery is the second most common surgery performed to treat
pharmacoresistant epilepsy. Yet, little is known about long-term seizure outcome following …
pharmacoresistant epilepsy. Yet, little is known about long-term seizure outcome following …
FDG-PET improves surgical outcome in negative MRI Taylor-type focal cortical dysplasias
F Chassoux, S Rodrigo, F Semah, F Beuvon, E Landre… - Neurology, 2010 - AAN Enterprises
Objective: To determine the diagnostic accuracy and prognostic value of 18FDG-PET in a
recent series of patients operated for intractable partial epilepsy associated with …
recent series of patients operated for intractable partial epilepsy associated with …
The role of radionuclide imaging in epilepsy, part 1: sporadic temporal and extratemporal lobe epilepsy
A Kumar, HT Chugani - Journal of Nuclear Medicine, 2013 - Soc Nuclear Med
Epilepsy is one of the most common yet diverse neurologic disorders, affecting almost 1%–
2% of the population. Presently, radionuclide imaging such as PET and SPECT is not used …
2% of the population. Presently, radionuclide imaging such as PET and SPECT is not used …
[HTML][HTML] Cerebral metabolism and perfusion in MR-negative individuals with refractory focal epilepsy assessed by simultaneous acquisition of 18F-FDG PET and …
IB Galazzo, MV Mattoli, FB Pizzini, E De Vita… - NeuroImage: Clinical, 2016 - Elsevier
The major challenge in pre-surgical epileptic patient evaluation is the correct identification of
the seizure onset area, especially in MR-negative patients. In this study, we aimed to:(1) …
the seizure onset area, especially in MR-negative patients. In this study, we aimed to:(1) …
The role of FDG-PET, ictal SPECT, and MEG in the epilepsy surgery evaluation
RC Knowlton - Epilepsy & Behavior, 2006 - Elsevier
2-[18F] Fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET), ictal single-
photon-emission computed tomography (ictal SPECT), and magnetoencephalography …
photon-emission computed tomography (ictal SPECT), and magnetoencephalography …
Relationship between PET metabolism and SEEG epileptogenicity in focal lesional epilepsy
S Lagarde, M Boucekine, A McGonigal… - European Journal of …, 2020 - Springer
Purpose This study aims to evaluate the performance of 18 F-FDG PET for distinguishing the
epileptogenic zone (EZ) from propagation and non-involved zones at brain area level, as …
epileptogenic zone (EZ) from propagation and non-involved zones at brain area level, as …
18F-FDG PET in drug-resistant epilepsy due to focal cortical dysplasia type 2: additional value of electroclinical data and coregistration with MRI
S Desarnaud, C Mellerio, F Semah, A Laurent… - European Journal of …, 2018 - Springer
Purpose To assess the localizing value of 18 F-FDG PET in patients operated on for drug-
resistant epilepsy due to focal cortical dysplasia type 2 (FCD 2). Methods We analysed 18 F …
resistant epilepsy due to focal cortical dysplasia type 2 (FCD 2). Methods We analysed 18 F …
[HTML][HTML] PET and ictal SPECT can be helpful for localizing epileptic foci
TJ von Oertzen - Current opinion in neurology, 2018 - journals.lww.com
PET and ictal SPECT can be helpful for localizing epileptic... : Current Opinion in Neurology PET
and ictal SPECT can be helpful for localizing epileptic foci : Current Opinion in Neurology Log …
and ictal SPECT can be helpful for localizing epileptic foci : Current Opinion in Neurology Log …