Adaptive statistical iterative reconstruction technique for pulmonary CT: image quality of the cadaveric lung on standard-and reduced-dose CT

M Yanagawa, O Honda, S Yoshida, A Kikuyama… - Academic radiology, 2010 - Elsevier
RATIONALE AND OBJECTIVES: To evaluate thin-section computed tomography (CT)
images of the lung reconstructed using adaptive statistical iterative reconstruction (ASIR) on …

Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study

S Sankaran, EC Frey, KL Gilland… - Journal of Nuclear …, 2002 - Soc Nuclear Med
Attenuation, photon scatter, and distance-dependent collimator-detector response are major
degrading factors in myocardial SPECT images. The current study investigated whether …

[PDF][PDF] Attenuation, scatter, and spatial resolution compensation in SPECT

MA King, SJ Glick, PH Pretorius, RG Wells… - … : the fundamentals of …, 2004 - nucmedinfo.com
Data acquisition for the case of ideal SPECT imaging is illustrated in Figure 1, which
portrays a single-headed gamma camera imaging a source distribution f (x, y) at a rotation …

Pediatric 99mTc-DMSA SPECT Performed by Using Iterative Reconstruction with Isotropic Resolution Recovery: Improved Image Quality and Reduced Radiopharmaceutical …

N Sheehy, TA Tetrault, D Zurakowski, AH Vija… - Radiology, 2009 - pubs.rsna.org
Purpose: To compare two methods of reconstructing technetium 99m (99mTc)
dimercaptosuccinic acid (DMSA) renal single photon emission computed tomographic …

Characterization of ordered-subsets expectation maximization with 3d post-reconstruction gauss filtering and comparison with filtered backprojection in99mTc SPECT

M Brambilla, B Cannillo, M Dominietto, L Leva… - Annals of nuclear …, 2005 - Springer
Purpose To characterize ordered-subset expectation maximization algorithm with a fixed 3D
Gauss post-reconstruction filtering (OSEM) in 99m Tc SPECT as for noise, contrast and …

Two‐dimensional iterative region‐of‐interest (ROI) reconstruction from truncated projection data

B Zhang, GL Zeng - Medical physics, 2007 - Wiley Online Library
A small detector or limited gantry rotation angles may cause data truncation, in which case
the entire object cannot be completely reconstructed. However, a small region of interest …

Patch-based image reconstruction for PET using prior-image derived dictionaries

MS Tahaei, AJ Reader - Physics in Medicine & Biology, 2016 - iopscience.iop.org
In PET image reconstruction, regularization is often needed to reduce the noise in the
resulting images. Patch-based image processing techniques have recently been …

Parallel CT image reconstruction based on GPUs

LA Flores, V Vidal, P Mayo, F Rodenas… - Radiation Physics and …, 2014 - Elsevier
In X-ray computed tomography (CT) iterative methods are more suitable for the
reconstruction of images with high contrast and precision in noisy conditions from a small …

LROC analysis of detector-response compensation in SPECT

HC Gifford, MA King, RG Wells… - … on Medical Imaging, 2000 - ieeexplore.ieee.org
Localization ROC (LROC) observer studies examined whether detector response
compensation (DRC) in ordered-subset, expectation-maximization (OSEM) reconstructions …

Assessment of scatter compensation strategies for 67Ga SPECT using numerical observers and human LROC studies

TH Farncombe, HC Gifford… - Journal of Nuclear …, 2004 - Soc Nuclear Med
67Ga citrate is an oncologic SPECT imaging agent often used to diagnose or stage patients
with non-Hodgkin's lymphoma. As 67Ga decay involves the emission of multiple-energy γ …