Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection

HWAM de Jong, ETP Slijpen… - IEEE Transactions on …, 2001 - ieeexplore.ieee.org
Monte Carlo (MC) simulation is an established tool to calculate photon transport through
tissue in Emission Computed Tomography (ECT). Since the first appearance of MC a large …

Image distortion and correction in single photon emission CT

K Ogawa - Annals of nuclear medicine, 2004 - Springer
The task of single photon emission CT (SPECT) is to visualize the physiological function of
various organs with the help of radiopharmaceuticals. But the projection data used for image …

Differential effect of 180 and 360 acquisition orbits on the accuracy of SPECT imaging: quantitative evaluation in phantoms

YH Liu, PT Lam, AJ Sinusas… - Journal of Nuclear …, 2002 - Soc Nuclear Med
A circular 180° acquisition orbit is considered standard for cardiac SPECT imaging.
Theoretically, a 360° acquisition orbit is preferred because of more complete Fourier …

[HTML][HTML] Application of Chang's attenuation correction technique for single-photon emission computed tomography partial angle acquisition of Jaszczak phantom

K Saha, SC Hoyt, BM Murray - Journal of Medical Physics, 2016 - journals.lww.com
The acquisition and processing of the Jaszczak phantom is a recommended test by the
American College of Radiology for evaluation of gamma camera system performance. To …

Evaluation of 3D Monte Carlo–based scatter correction for 201Tl cardiac perfusion SPECT

J Xiao, TC De Wit, W Zbijewski… - Journal of Nuclear …, 2007 - Soc Nuclear Med
201Tl-Chloride (201Tl) is a myocardial perfusion SPECT agent with excellent biochemical
properties commonly used for assessing tissue viability. However, cardiac 201Tl SPECT …

Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom

T Ito, H Tsuchikame, H Ichikawa, M Onoguchi… - … Physics and Technology, 2021 - Springer
We aimed to compare the measurement and simulation data of bone scintigraphy of a chest
phantom using a Monte Carlo simulation to verify the accuracy of the simulated data. The …

Comparison of 180° and 360° acquisition for myocardial perfusion SPECT with compensation for attenuation, detector response, and scatter: Monte Carlo and …

X He, JM Links, KL Gilland, BMW Tsui… - Journal of nuclear …, 2006 - Springer
Background The optimal projection data acquisition strategy for myocardial perfusion (MP)
single photon emission computed tomography (SPECT) remains controversial. Methods We …

Attenuation and scatter compensation in myocardial perfusion SPECT

JR Galt, SJ Cullom, EV Garcia - Seminars in nuclear medicine, 1999 - Elsevier
Nonuniform attenuation, Compton scatter, and limited, spatially varying resolution degrade
both the qualitative and quantitative nature of myocardial perfusion SPECT. Physicians must …

Effect of tomographic orbit and type of rotation on apparent myocardial activity

MK O'Connor, CB Hruska - Nuclear medicine communications, 2005 - journals.lww.com
Objectives In myocardial perfusion imaging, the type of orbit that provides the best image
quality is still the subject of debate. This study correlates the effects of angular rotation (180 …

[PDF][PDF] Assessment of infarct size and severity by quantitative myocardial SPECT: results from a multicenter study using a cardiac phantom

MK O'Connor, LK Leong… - Journal of Nuclear …, 2000 - Soc Nuclear Med
The aim of this study was to determine the reproducibility of measurements of the size and
severity of myocardial defects from" mTc sestamibi cardiac phantom studies performed on …