EANM/ESC guidelines for radionuclide imaging of cardiac function

B Hesse, TB Lindhardt, W Acampa… - European journal of …, 2008 - Springer
Radionuclide imaging of cardiac function represents a number of well-validated techniques
for accurate determination of right (RV) and left ventricular (LV) ejection fraction (EF) and LV …

[HTML][HTML] Equilibrium radionuclide angiocardiography: Its usefulness in current practice and potential future applications

D Mitra, S Basu - World journal of radiology, 2012 - ncbi.nlm.nih.gov
The routine and potential future applications of equilibrium radionuclide angiocardiography/
multigated acquisition (MUGA) in clinical decision making are explored in this review. The …

Equilibrium radionuclide angiocardiography

JR Corbett, OO Akinboboye, SL Bacharach… - Journal of Nuclear …, 2006 - Springer
Planar equilibrium radionuclide angiography (ERNA) is used to determine global and
regional measures of ventricular function (primarily left ventricular [LV] function) at rest …

Validation of SPECT equilibrium radionuclide angiographic right ventricular parameters by cardiac magnetic resonance imaging

K Nichols, R Saouaf, AA Ababneh, RJ Barst… - Journal of nuclear …, 2002 - Springer
Background Recent advances in the treatment of primary pulmonary hypertension (PPH),
and in surgery to correct tetralogy of Fallot (TOF), have rekindled interest in evaluating right …

Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT

SD Van Kriekinge, DS Berman, G Germano - Journal of Nuclear …, 1999 - Springer
Background Cardiac gated blood pool single photon emission computed tomography
(GBPS) better separates cardiac chambers compared with planar radionuclide …

Planar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: a multicenter study

MW Groch, EG DePuey, AC Belzberg… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Gated blood-pool SPECT (GBPS), inherently 3-dimensional (3D), has the potential to
replace planar equilibrium radionuclide angiography (ERNA) for computation of left …

Automatic quantification of right ventricular function with gated blood pool SPECT

D Daou, SDV Kriekinge, C Coaguila, R Lebtahi… - Journal of nuclear …, 2004 - Springer
Background Quantification of right ventricular (RV) function is clinically relevant for the risk
stratification and follow-up of patients with a wide spectrum of disease. This can be achieved …

Clinical validation of the gated blood pool SPECT QBS® processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D …

M Hacker, X Hoyer, S Kupzyk, CL Fougere… - The international journal …, 2006 - Springer
Introduction Left (LVEF) and right ventricular ejection fraction (RVEF) as well as LV regional
wall motion at rest are valuable tools to monitor and tailor treatment of congestive heart …

Radiation reduction and faster acquisition times with SPECT gated blood pool scans using a high-efficiency cardiac SPECT camera

WL Duvall, KA Guma-Demers, T George… - Journal of Nuclear …, 2016 - Elsevier
Background Planar gated blood pool scans are an established method for the evaluation of
left ventricular ejection fraction (LVEF) but the camera technology used for these studies has …

Left ventricle function assessment using gated first-pass 18F-FDG PET: Validation against equilibrium radionuclide angiography

F Ben Bouallègue, L Maïmoun, F Kucharczak… - Journal of Nuclear …, 2021 - Springer
Purpose We appraised the feasibility of left ventricle (LV) function assessment using gated
first-pass 18 F-FDG PET, and assessed the concordance of the produced measurements …