Radiopharmaceuticals for brain imaging

GB Saha, WJ MacIntyre, RT Go - Seminars in nuclear medicine, 1994 - Elsevier
Brain imaging is performed using radiopharmaceuticals by single photon emission
computed tomography (SPECT) and positron emission tomography (PET). SPECT and PET …

Myocardial blood flow distribution in patients with ischemic heart disease or dilated cardiomyopathy undergoing heart transplantation.

O Parodi, R De Maria, L Oltrona, R Testa… - Circulation, 1993 - Am Heart Assoc
BACKGROUND The present investigation was designed to obtain an absolute
measurement of myocardial blood flow and of its transmural distribution in ischemic heart …

Intratumoral arteriovenous shunting in malignant gliomas

L Mariani, G Schroth, JP Wielepp, A Haldemann… - …, 2001 - journals.lww.com
METHODS: Using a previously described technique of selective intra-arterial intratumoral
injection of 99m Tc-labeled microparticles (macroaggregated albumin), we measured the …

N-isopropyl (I-123) p-iodoamphetamine brain scans with single-photon emission tomography: discordance with transmission computed tomography.

RG Lee, TC Hill, BL Holman, ME Clouse - Radiology, 1982 - pubs.rsna.org
Transmission computed tomography (CT) brain scans were compared with N-isopropyl (I-
123)-p-iodoamphetamine (IMP) single-photon emission computed tomography (SPECT) …

Assessment of regional cerebral blood flow by continuous carotid infusion of krypton-81m.

F Fazio, M Nardini, C Fieschi, C Forli - Journal of Nuclear Medicine …, 1977 - europepmc.org
In order to obtain functional images of brain perfusion, we exploited a new concept, which is
to take advantage of the short half-life of a radioactive tracer. Under continuous intracarotid …

Radionuclide detection, localization, and quantitation of intracardiac shunts and shunts between the great arteries

JA Parker, S Treves - Progress in Cardiovascular Diseases, 1977 - Elsevier
The application of radionuclides to the study of the cardiovascular system was first
investigated by Blumgart and Yens' and Blumgart and Weiss” nearly one-half century ago …

Residual coronary reserve despite decreased resting blood flow in patients with critical coronary lesions. A study by technetium-99m human albumin microsphere …

O Parodi, G Sambuceti, A Roghi, R Testa, E Inglese… - Circulation, 1993 - Am Heart Assoc
BACKGROUND Experimental data demonstrate the persistence of a transmural vasodilator
reserve in the face of depressed resting myocardial perfusion. The present study was …

Pediatric nuclear cardiology

MJ Gelfand, DW Hannon - Cardiac nuclear medicine, 1987 - inis.iaea.org
[en] Nuclear cardiology methods have had less impact upon pediatric cardiology than upon
adult cardiology. Most pediatric heart disease results from congenital malformations of the …

Radionuclide investigation of congenital heart disease

E BAKER - Heart, 2000 - heart.bmj.com
In a previous issue of Heart, Verttukattil and colleagues presented a study of intrapulmonary
arteriovenous shunting after a superior cavopulmonary anastomosis using radionuclide …

Carotid-cavernous fistula: demonstration of asymptomatic vascular “steal”

BD Barnes, ML Rosenblum, LH Pitts… - Journal of …, 1978 - thejns.org
✓ Abnormal distribution of cerebral vascular flow was studied in a patient who had a
traumatic carotid-cavernous sinus fistula. Serial studies were performed using a method for …