[BOOK][B] Positron emission tomography
DL Bailey, MN Maisey, DW Townsend, PE Valk - 2005 - Springer
The aim of that book was to address what we perceived of as a lack, at the time, of a
comprehensive contemporary reference work on the rapidly expanding area of positron …
comprehensive contemporary reference work on the rapidly expanding area of positron …
PET instrumentation: what are the limits?
TF Budinger - Seminars in nuclear medicine, 1998 - Elsevier
This report has emphasized the attributes of positron emission tomography (PET) through a
discussion of the historical development with attention to limitations or factors that are of …
discussion of the historical development with attention to limitations or factors that are of …
The preparation of fluorine-18 labelled radiopharmaceuticals
AJ Palmer, JC Clark, RW Goulding - The International Journal of Applied …, 1977 - Elsevier
Progress in the preparation of fluorine-18 labelled radiopharmaceuticals is reviewed. The
pharmacology and design of 18 F-labelled organic compounds of biomedical interest …
pharmacology and design of 18 F-labelled organic compounds of biomedical interest …
High resolution computed tomography of positron emitters
SE Derenzo, TF Budinger, JL Cahoon… - IEEE transactions on …, 1977 - ieeexplore.ieee.org
High resolution computed transaxial tomography has been performed on phantoms
containing positron-emitting isotopes. The imaging system consisted of two opposing groups …
containing positron-emitting isotopes. The imaging system consisted of two opposing groups …
Performance parameters of a positron imaging camera
G Muehllehner, MP Buchin… - IEEE Transactions on …, 1976 - ieeexplore.ieee.org
Two Anger scintillation cameras have been combined into a positron imaging system. Count
rate capability has been extended by using absorbers to reduce scattered radiation from the …
rate capability has been extended by using absorbers to reduce scattered radiation from the …
[PDF][PDF] Analytical study of a high-resolution positron ring detector system for transaxial reconstruction tomography
SE Derenzo, H Zaklad, TF Budinger - Journal of Nuclear Medicine, 1975 - Soc Nuclear Med
ANALYTICAL STUDY OF A HIGH-RESOLUTION POSITRON RING DETECTOR SYSTEM FOR
TRANSAXIAL RECONSTRUCTION TOMOGRAPHY Page 1 ANALYTICAL STUDY OF A …
TRANSAXIAL RECONSTRUCTION TOMOGRAPHY Page 1 ANALYTICAL STUDY OF A …
Data acquisition and performance characterization in PET
DL Bailey - Positron emission tomography: basic sciences, 2005 - Springer
Positron emission detection systems have developed since their first use in the 1950s to the
high-resolution, high-sensitivity tomographic devices that we have today. Configurations …
high-resolution, high-sensitivity tomographic devices that we have today. Configurations …
Three-dimensional imaging in the positron camera using Fourier techniques
G Chu, KC Tam - Physics in Medicine & Biology, 1977 - iopscience.iop.org
A mathematical algorithm for three-dimensional reconstructions in the positron camera is
described. Fourier techniques have been adapted for use in analysing the data from …
described. Fourier techniques have been adapted for use in analysing the data from …
ECAT ART—a continuously rotating PET camera: performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department
Advances in fully three-dimensional (3D) image reconstruction techniques have permitted
the development of a commercial, rotating, partial ring, fully 3D positron emission …
the development of a commercial, rotating, partial ring, fully 3D positron emission …
[PDF][PDF] Coincidence imaging with a dual-head scintillation camera
JA Patton, TG Turkington - Journal of Nuclear Medicine, 1999 - Soc Nuclear Med
Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center,
Nashville, Tennessee; and the Department of Radiology, Duke University Medical Center …
Nashville, Tennessee; and the Department of Radiology, Duke University Medical Center …