Modeling of the GELINA neutron target using coupled electron–photon–neutron transport with the MCNP4C3 code

…, D Lathouwers, LC Mihailescu, W Mondelaers… - Nuclear Instruments and …, 2004 - Elsevier
Coupled electron–photon–neutron transport calculations were performed with the Monte
Carlo code MCNP4C3 to model the GELINA neutron target. Our calculations were compared …

Comparison of the effect of X-ray and electron beam irradiation on some selected spices

…, O Van Cleemput, F Callens, W Mondelaers… - LWT-Food Science and …, 1998 - Elsevier
The effect of irradiation with X-rays and electron beams on the microbiological quality of
white pepper, sweet red paprika and nutmeg was examined. Statistical analyses were …

Density functional calculations of hyperfine coupling constants in alanine-derived radicals

…, F Callens, P Geerlings, W Mondelaers - The Journal of …, 1999 - ACS Publications
We present the results of density functional calculations of 1 H, 13 C, and 14 N hyperfine
coupling constants (hfcc's) in radicals derived from the simple amino acid l-alanine. The …

Absorbed dose beam quality correction factors for the NE2571 chamber in a 5 MV and a 10 MV photon beam

H Palmans, W Mondelaers… - Physics in Medicine & …, 1999 - iopscience.iop.org
Dose to water determination in clinical high-energy photon beams with ionization chambers
calibrated in terms of absorbed dose to water has been proposed as an alternative to …

Effects of X-irradiation on adventitious bud regeneration from in vitro leaf explants of Rosa hybrida

R Ibrahim, W Mondelaers, PC Debergh - Plant cell, tissue and organ …, 1998 - Springer
The effectiveness of X-radiation on regeneration of adventitious buds on in vitro leaf explants
of three Rosa hybrida L. genotypes was studied. In vitro leaflet explants of roses produced …

Electron magnetic resonance study of stable radicals in irradiated D-fructose single crystals

…, P Lahorte, F De Proft, W Mondelaers… - Physical Chemistry …, 2001 - pubs.rsc.org
The electron paramagnetic resonance (EPR) spectra of irradiated mono and oligosaccharides
are very complex because of their multicomponent character. A multivariate statistical …

[PDF][PDF] Technetium-99m-MDP scintigraphy and long-term follow-up of treated primary malignant bone tumors

…, K Casier, D Uyttendaele, W Mondelaers… - Journal of Nuclear …, 1998 - Soc Nuclear Med
Local malignant bone tumor excision followed by high-dose extra corporeal irradiation (300
Gy) and subsequent reimplantation is a unique technique for treatment of primary bone and …

Decomposition study of the electron paramagnetic resonance spectrum of irradiated alanine

…, SA Amira, WKPG Mondelaers… - … Acta Part A: Molecular …, 2000 - Elsevier
Recent Electron Paramagnetic Resonance (EPR) studies on alanine powders as a function
of irradiation dose and temperature on the one hand and single crystal Electron Nuclear …

Grating transition radiation: A source of quasimonochromatic radiation

…, O Haeberlé, P Rullhusen, N Maene, W Mondelaers - Physical Review E, 1999 - APS
We have observed transition radiation at optical wavelengths, emitted by 3–13-MeV electrons
interacting with a diffraction grating. Near the direction of specular reflection we observed …

Effect of temperature on the electron paramagnetic resonance spectrum of irradiated alanine

GCAM Vanhaelewyn, WKPG Mondelaers… - Radiation …, 1999 - meridian.allenpress.com
Polycrystalline samples of the amino acid L-α-alanine have been irradiated with X rays at
both room temperature and higher temperatures. The electron paramagnetic resonance (EPR) …