User profiles for Vladimir Y. Panin

Vladimir Y Panin

Principal Key Expert, Siemens Medical Solutions USA
Verified email at siemens-healthineers.com
Cited by 3347

Fully 3-D PET reconstruction with system matrix derived from point source measurements

VY Panin, F Kehren, C Michel… - IEEE transactions on …, 2006 - ieeexplore.ieee.org
The quality of images reconstructed by statistical iterative methods depends on an accurate
model of the relationship between image space and projection space through the system …

An assessment of the impact of incorporating time-of-flight information into clinical PET/CT imaging

…, ME Casey, M Conti, VY Panin… - Journal of Nuclear …, 2010 - Soc Nuclear Med
The introduction of fast scintillators with good stopping power for 511-keV photons has
renewed interest in time-of-flight (TOF) PET. The ability to measure the difference between the …

Dynamic whole-body PET imaging: principles, potentials and applications

…, MA Lodge, NA Karakatsanis, VY Panin, Y Zhou… - European journal of …, 2019 - Springer
Purpose In this article, we discuss dynamic whole-body (DWB) positron emission tomography
(PET) as an imaging tool with significant clinical potential, in relation to conventional …

Data-driven voluntary body motion detection and non-rigid event-by-event correction for static and dynamic PET

…, N Boutagy, T Mulnix, VY Panin… - Physics in Medicine …, 2019 - iopscience.iop.org
PET has the potential to perform absolute in vivo radiotracer quantitation. This potential can
be compromised by voluntary body motion (BM), which degrades image resolution, alters …

Experimental comparison of lesion detectability for four fully-3D PET reconstruction schemes

…, NF Black, JJ Hamill, VY Panin… - IEEE transactions on …, 2008 - ieeexplore.ieee.org
The objective of this work was to evaluate the lesion detection performance of four fully-3D
positron emission tomography (PET) reconstruction schemes using experimentally acquired …

Metal artifact reduction of CT scans to improve PET/CT

…, JJ Hamill, C Hofmann, VY Panin… - Journal of Nuclear …, 2017 - Soc Nuclear Med
In recent years, different metal artifact reduction methods have been developed for CT.
These methods have only recently been introduced for PET/CT even though they could be …

Restoration of fine azimuthal sampling of measured TOF projection data

VY Panin, M Defrise, ME Casey - IEEE Nuclear Science …, 2010 - ieeexplore.ieee.org
TOF acquisition results in additional data dimensions that significantly increase data size.
Due to the redundancy of TOF information, data can be compressed almost without loss of …

Reconstruction of uniform sensitivity emission image with partially known axial attenuation information in PET-CT scanners

VY Panin, M Defrise, J Nuyts, A Rezaei… - 2012 IEEE nuclear …, 2012 - ieeexplore.ieee.org
In PET-CT the axial length of image reconstruction is defined by the CT scan, which delivers
an axial extend-dependent radiation dose. The beginning and end scanning points for CT …

Diffusion tensor MR imaging of principal directions: a tensor tomography approach

VY Panin, GL Zeng, M Defrise… - Physics in Medicine & …, 2002 - iopscience.iop.org
A novel approach to reconstructing the principal directions of a diffusion tensor field directly
from magnetic resonance imaging (MRI) data using a tensor tomography data acquisition …

Evaluation of MLACF based calculated attenuation brain PET imaging for FDG patient studies

H Bal, VY Panin, G Platsch, M Defrise… - Physics in Medicine …, 2017 - iopscience.iop.org
Calculating attenuation correction for brain PET imaging rather than using CT presents
opportunities for low radiation dose applications such as pediatric imaging and serial scans to …