User profiles for Thiago V. M. Lima

Thiago VM Lima

Medical Physics Expert
Verified email at luks.ch
Cited by 182

Swiss survey on hybrid imaging CTs doses in nuclear medicine and proposed national dose reference levels

TVM Lima, S Gnesin, N Ryckx, K Strobel, N Stritt… - … für Medizinische Physik, 2018 - Elsevier
A multidisciplinary working group led by the Swiss Federal Office of Public Health was
formed to plan and perform a nationwide survey of patient radiation exposure from computed …

[HTML][HTML] Phantom-based image quality assessment of clinical 18F-FDG protocols in digital PET/CT and comparison to conventional PMT-based PET/CT

…, R Guignard, JO Prior, FR Verdun, TVM Lima - EJNMMI physics, 2020 - Springer
Background We assessed and compared image quality obtained with clinical 18 F-FDG
whole-body oncologic PET protocols used in three different, state-of-the-art digital PET/CT and …

[HTML][HTML] Fifty shades of scandium: comparative study of PET capabilities using Sc-43 and Sc-44 with respect to conventional clinical radionuclides

TVM Lima, S Gnesin, K Strobel, MS Pérez, JE Roos… - Diagnostics, 2021 - mdpi.com
Scandium-44 has been proposed as a valuable radionuclide for Positron Emission Tomography
(PET). Recently, scandium-43 was introduced as a more favorable option, as it does not …

A multicenter study on observed discrepancies between vendor-stated and PET-measured 90Y activities for both glass and resin microsphere devices

…, M Conti, JO Prior, T Carlier, TVM Lima… - Journal of Nuclear …, 2023 - Soc Nuclear Med
Dosimetry-guided treatment planning in selective internal radiation therapy relies on accurate
and reproducible measurement of administered activity. This 4-center, 5-PET-device study …

Usefulness of augmented reality in radiological protection education and training for interventional radiologists

TVM Lima… - The British Journal of …, 2023 - academic.oup.com
Objective: The aim of this work is to evaluate the usefulness of using augmented reality (AR)
to train medical professionals in radiological protection (RP) in fluoroscopy. Methods: A …

Calculation of absorbed dose in paediatric phantoms using Monte Carlo techniques for 18F-FDG and 99mTc-DMSA and the new TIAC

CVG Ferreira, BM Mendes, L Paixão, TVM Lima… - Applied Radiation and …, 2023 - Elsevier
The radiopharmaceuticals most commonly used in nuclear medicine are 18 F-FDG and 99
m Tc-DMSA, both of which are administered to paediatric and adult patients using the same …

[HTML][HTML] Monte Carlo calculations supporting patient plan verification in proton therapy

TVM Lima, M Dosanjh, A Ferrari, S Molineli… - Frontiers in …, 2016 - frontiersin.org
Patient’s treatment plan verification covers substantial amount of the quality assurance (QA)
resources; this is especially true for Intensity-Modulated Proton Therapy (IMPT). The use of …

[HTML][HTML] First phantom-based quantitative assessment of scandium-44 using a commercial PET device

TVM Lima, S Gnesin, E Nitzsche, PG Ortega… - Frontiers in …, 2020 - frontiersin.org
Scandium (Sc) is a promising candidate for theranostic applications due to the existence of
radioisotopes suitable for both imaging and therapy. A “proof-of-concept” study regarding first-…

[HTML][HTML] Impact of metal implants on xSPECT/CT Bone reconstruction: the “shining metal artefact”

TVM Lima, U Bhure, MS Pérez Lago, Y Thali… - European journal of …, 2020 - Springer
Background Novel reconstruction algorithms, such as xSPECT Bone, are gaining more and
more importance in Nuclear Medicine. With xSPECT Bone, the reconstructed emission …

Review of the role of bone-SPECT/CT in tarsal coalitions

…, B Bosmans, RHJA Slart, TVM Lima… - Nuclear medicine …, 2023 - journals.lww.com
Tarsal coalition (TC) is a congenital abnormal connection (fibrous, cartilaginous, or osseous)
between two or more bones in the hind and midfoot, mostly consisting of calcaneonavicular …