A quantitative approach to technetium-99m ethyl cysteinate dimer: a comparison with technetium-99m hexamethylpropylene amine oxime
H Matsuda, A Yagishita, S Tsuji, K Hisada - European journal of nuclear …, 1995 - Springer
To develop non-invasive regional cerebral blood flow (rCBF) measurements using
technetium-99m ethyl cysteinate dimer ( 99m Tc-ECD) and single-photon emission tomography (…
technetium-99m ethyl cysteinate dimer ( 99m Tc-ECD) and single-photon emission tomography (…
Noninvasive measurements of regional cerebral blood flow using technetium-99m hexamethylprophylene amine oxime
H Matsuda, S Tsuji, N Shuke, H Sumiya… - European journal of …, 1993 - Springer
The previously reported method for quantitative measurements of whole-brain or
hemispheric-brain perfusion using technetium-99m hexamethylpropylene amine oxime (HMPAO) …
hemispheric-brain perfusion using technetium-99m hexamethylpropylene amine oxime (HMPAO) …
A quantitative approach to technetium-99m hexamethylpropylene amine oxime
H Matsuda, S Tsuji, N Shuke, H Sumiya… - European journal of …, 1992 - Springer
A non-invasive, simple method for the quantitative evaluation of brain perfusion is presented
using intravenous radionuclide angiography with technetium-99m hexamethylpropylene …
using intravenous radionuclide angiography with technetium-99m hexamethylpropylene …
Changes in regional cerebral blood flow in irradiated regions and normal brain after stereotactic radiosurgery
…, K Higashi, M Oguchi, H Tamamura, S Tsuji… - Annals of nuclear …, 2002 - Springer
Objective: To elucidate the radiation effect on the normal brain after stereotactic radiosurgery
(SRS), we evaluated the change in regional cerebral blood flow (CBF) in targeted and extra…
(SRS), we evaluated the change in regional cerebral blood flow (CBF) in targeted and extra…
High resolution Tc-99m HMPAO SPECT in a patient with transient global amnesia
This is a report of a patient who underwent high-resolution brain perfusion SPECT studies
during and after an episode of transient global amnesia. During the attack, SPECT imaging …
during and after an episode of transient global amnesia. During the attack, SPECT imaging …
SPECT evaluation of brain perfusion reserve by the acetazolamide test using Tc-99m HMPAO
…, S HIGASHI, K KINUYA, S TSUJI… - Clinical Nuclear …, 1991 - journals.lww.com
This report describes a new approach to the evaluation of brain perfusion reserve using Tc-99m
HMPAO SPECT. Consecutive brain Tc-99m HMPAO SPECT studies before and after …
HMPAO SPECT. Consecutive brain Tc-99m HMPAO SPECT studies before and after …
Reversible cerebral hypoperfusion observed with Tc-99m HMPAO SPECT in reversible dementia caused by hypothyroidism
…, T Michigishi, N Tonami, T Aburano, S Tsuji… - Clinical nuclear …, 1999 - journals.lww.com
A 69-year-old man had hypothyroid dementia as a result of I-131 therapy and an overdose
of methimazole. Tc-99m HMPAO SPECT revealed diffuse cerebral hypoperfusion. The …
of methimazole. Tc-99m HMPAO SPECT revealed diffuse cerebral hypoperfusion. The …
Magnesium attenuates isoproterenol-induced acute cardiac dysfunction and β-adrenergic desensitization
…, S Natori, T Ohta, S Tsuji… - American Journal …, 2007 - journals.physiology.org
Sympathetic nervous activation is a crucial compensatory mechanism in heart failure. However,
excess catecholamine may induce cardiac dysfunction and β-adrenergic desensitization…
excess catecholamine may induce cardiac dysfunction and β-adrenergic desensitization…
Pulmonary blood flow evaluation using a dynamic flat-panel detector: feasibility study with pulmonary diseases
…, S Sanada, M Fujimura, M Yasui, S Tsuji… - International journal of …, 2009 - Springer
Purpose Pulmonary ventilation and circulation dynamics are reflected on fluoroscopic
images as changes in X-ray translucency. The purpose of this study was to investigate the …
images as changes in X-ray translucency. The purpose of this study was to investigate the …
[HTML][HTML] Cross calibration of 123I-meta-iodobenzylguanidine heart-to-mediastinum ratio with D-SPECT planogram and Anger camera
…, K Okuda, K Yokoyama, T Yoneyama, S Tsuji… - Annals of Nuclear …, 2017 - Springer
Background Cardiac 123 I-meta-iodobenzylguanidine (MIBG) uptake is quantified using the
heart-to-mediastinum ratio (HMR) with an Anger camera. The relationship between HMR …
heart-to-mediastinum ratio (HMR) with an Anger camera. The relationship between HMR …