A quantitative approach to technetium-99m ethyl cysteinate dimer: a comparison with technetium-99m hexamethylpropylene amine oxime

H Matsuda, A Yagishita, S Tsuji, K Hisada - European journal of nuclear …, 1995 - Springer
To develop non-invasive regional cerebral blood flow (rCBF) measurements using
technetium-99m ethyl cysteinate dimer ( 99m Tc-ECD) and single-photon emission tomography (…

Noninvasive measurements of regional cerebral blood flow using technetium-99m hexamethylprophylene amine oxime

H Matsuda, S Tsuji, N Shuke, H Sumiya… - European journal of …, 1993 - Springer
The previously reported method for quantitative measurements of whole-brain or
hemispheric-brain perfusion using technetium-99m hexamethylpropylene amine oxime (HMPAO) …

A quantitative approach to technetium-99m hexamethylpropylene amine oxime

H Matsuda, S Tsuji, N Shuke, H Sumiya… - European journal of …, 1992 - Springer
A non-invasive, simple method for the quantitative evaluation of brain perfusion is presented
using intravenous radionuclide angiography with technetium-99m hexamethylpropylene …

Changes in regional cerebral blood flow in irradiated regions and normal brain after stereotactic radiosurgery

…, K Higashi, M Oguchi, H Tamamura, S Tsuji… - Annals of nuclear …, 2002 - Springer
Objective: To elucidate the radiation effect on the normal brain after stereotactic radiosurgery
(SRS), we evaluated the change in regional cerebral blood flow (CBF) in targeted and extra…

High resolution Tc-99m HMPAO SPECT in a patient with transient global amnesia

H MATSUDA, S HIGASHI, S TSUJI… - Clinical nuclear …, 1993 - journals.lww.com
This is a report of a patient who underwent high-resolution brain perfusion SPECT studies
during and after an episode of transient global amnesia. During the attack, SPECT imaging …

SPECT evaluation of brain perfusion reserve by the acetazolamide test using Tc-99m HMPAO

…, S HIGASHI, K KINUYA, S TSUJI… - Clinical Nuclear …, 1991 - journals.lww.com
This report describes a new approach to the evaluation of brain perfusion reserve using Tc-99m
HMPAO SPECT. Consecutive brain Tc-99m HMPAO SPECT studies before and after …

Reversible cerebral hypoperfusion observed with Tc-99m HMPAO SPECT in reversible dementia caused by hypothyroidism

…, T Michigishi, N Tonami, T Aburano, S Tsuji… - Clinical nuclear …, 1999 - journals.lww.com
A 69-year-old man had hypothyroid dementia as a result of I-131 therapy and an overdose
of methimazole. Tc-99m HMPAO SPECT revealed diffuse cerebral hypoperfusion. The …

Magnesium attenuates isoproterenol-induced acute cardiac dysfunction and β-adrenergic desensitization

…, S Natori, T Ohta, S Tsuji… - American Journal …, 2007 - journals.physiology.org
Sympathetic nervous activation is a crucial compensatory mechanism in heart failure. However,
excess catecholamine may induce cardiac dysfunction and β-adrenergic desensitization…

Pulmonary blood flow evaluation using a dynamic flat-panel detector: feasibility study with pulmonary diseases

…, S Sanada, M Fujimura, M Yasui, S Tsuji… - International journal of …, 2009 - Springer
Purpose Pulmonary ventilation and circulation dynamics are reflected on fluoroscopic
images as changes in X-ray translucency. The purpose of this study was to investigate the …

[HTML][HTML] Cross calibration of 123I-meta-iodobenzylguanidine heart-to-mediastinum ratio with D-SPECT planogram and Anger camera

…, K Okuda, K Yokoyama, T Yoneyama, S Tsuji… - Annals of Nuclear …, 2017 - Springer
Background Cardiac 123 I-meta-iodobenzylguanidine (MIBG) uptake is quantified using the
heart-to-mediastinum ratio (HMR) with an Anger camera. The relationship between HMR …