Phase I/II trial of electrophysiology-guided noninvasive cardiac radioablation for ventricular tachycardia
Background: Case studies have suggested the efficacy of catheter-free, electrophysiology-guided
noninvasive cardiac radioablation for ventricular tachycardia (VT) using stereotactic …
noninvasive cardiac radioablation for ventricular tachycardia (VT) using stereotactic …
QA for helical tomotherapy: report of the AAPM task group 148 a
…, J Balog, R Crilly, D Followill, SM Goddu… - Medical …, 2010 - Wiley Online Library
… for more than 3 s or (ii) the monitor chamber readings differ by more than 5% from their
nominal rate for more than three consecutive rolling 10 s windows. A new 10 s window is started …
nominal rate for more than three consecutive rolling 10 s windows. A new 10 s window is started …
Verification of monitor unit calculations for non‐IMRT clinical radiotherapy: report of AAPM Task Group 114
…, R Heaton, MW Fraser, S Murty Goddu… - Medical …, 2011 - Wiley Online Library
The requirement of an independent verification of the monitor units (MU) or time calculated
to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality …
to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality …
[PDF][PDF] Multicellular dosimetry for micrometastases: dependence of self-dose versus cross-dose to cell nuclei on type and energy of radiation and subcellular …
SM Goddu, DV Rao, RW Howell - Journal of Nuclear Medicine, 1994 - Soc Nuclear Med
The present work systematically examines the self-dose and cross-dose contributions from
intracellularradioactiv ity within small micrometastases. Model calculations are performed to …
intracellularradioactiv ity within small micrometastases. Model calculations are performed to …
DIRART – A software suite for deformable image registration and adaptive radiotherapy research
…, A Aditya, Y Wu, S Murty Goddu, S Mutic… - Medical …, 2011 - Wiley Online Library
Purpose: Recent years have witnessed tremendous progress in image guide radiotherapy
technology and a growing interest in the possibilities for adapting treatment planning and …
technology and a growing interest in the possibilities for adapting treatment planning and …
Cellular dosimetry: absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell …
SM Goddu, RW Howell, DV Rao - Journal of nuclear medicine …, 1994 - europepmc.org
… calculate cellular S-values for several radionuclides. … , S-values are given for radionuclides
in the 212Pb decay series, including 212Pb, 212Bi and 212Po. Both absorbed fractions and S…
in the 212Pb decay series, including 212Pb, 212Bi and 212Po. Both absorbed fractions and S…
Helical tomotherapy planning for left-sided breast cancer patients with positive lymph nodes: comparison to conventional multiport breast technique
SM Goddu, S Chaudhari, M Mamalui-Hunter… - International Journal of …, 2009 - Elsevier
PURPOSE: To evaluate the feasibility of using helical tomotherapy for locally advanced left-sided
breast cancer. METHODS AND MATERIALS: Treatment plans were generated for 10 …
breast cancer. METHODS AND MATERIALS: Treatment plans were generated for 10 …
[PDF][PDF] Considerations in the selection of radiopharmaceuticals for palliation of bone pain from metastatic osseous lesions
LG Bouchet, WE Bolch, SM Goddu… - Journal of Nuclear …, 2000 - Soc Nuclear Med
… Errors in the S values when the source and target regions are the same was <5% for all 3
radionuclides. RAFs calculated using S values that considered the x-ray/ â€y-raycomponent of …
radionuclides. RAFs calculated using S values that considered the x-ray/ â€y-raycomponent of …
Multimodality image registration quality assurance for conformal three-dimensional treatment planning
Purpose: We present a quality assurance methodology to determine the accuracy of
multimodality image registration and fusion for the purpose of conformal three-dimensional and …
multimodality image registration and fusion for the purpose of conformal three-dimensional and …
Daily QA of linear accelerators using only EPID and OBI
B Sun, SM Goddu, S Yaddanapudi, C Noel… - Medical …, 2015 - Wiley Online Library
Purpose: As treatment delivery becomes more complex, there is a pressing need for robust
quality assurance (QA) tools to improve efficiency and comprehensiveness while …
quality assurance (QA) tools to improve efficiency and comprehensiveness while …