Radiolabeled peptides in oncology: role in diagnosis and treatment

RE Weiner, ML Thakur - BioDrugs, 2005 - Springer
e) Posterior whole body planar images (4h post-injection, 6 mCi) after surgery (reproduced
from Weiner … from Weiner and Thakur,[77] with permission from John Wiley & Sons Limited]. …

Radiolabeled peptides in the diagnosis and therapy of oncological diseases

RE Weiner, ML Thakur - Applied Radiation and Isotopes, 2002 - Elsevier
There has been an exponential growth in the development of radiolabeled peptides for
diagnostic and therapeutic applications in oncology. Peptides have fast clearance, rapid tissue …

Radiolabeled peptides in diagnosis and therapy

RE Weiner, ML Thakur - Seminars in nuclear medicine, 2001 - Elsevier
During the past few years, there has been exponential growth in the development of radiolabeled
peptides for diagnosis and therapy. This is because the peptides can be synthesized …

The molecular properties of the copper enzyme galactose oxidase

DJ Kosman, MJ Ettinger, RE Weiner… - Archives of Biochemistry …, 1974 - Elsevier
Galactose oxidase (EC 1.1.3.9) has been purified 140-fold by DEAE- and CM-cellulose
chromatography from cultures of Polyporus circinatus. The enzyme has a molecular weight of …

In vitro transfer of Ga-67 from transferrin to ferritin.

RE Weiner, GJ Schreiber, PB Hoffer - Journal of Nuclear Medicine …, 1983 - europepmc.org
Equilibrium dialysis was used to examine the binding of Ga-67 to horse spleen ferritin (HFE),
and the ability of this protein to remove Ga-67 originally bound to human transferrin (TF). …

Early detection of oleic acid-induced lung injury in rats using 111In-labeled anti-rat intercellular adhesion molecule-1

RE Weiner, DE Sasso, MA Gionfriddo… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Previous study of the bleomycin-induced lung injury model suggested that 111 In-labeled
antirat intercellular adhesion molecule-1 (aICAM-1) might be a useful acute respiratory …

Simplified solid-state labeling of [123I] m-iodobenzylguanidine

BH Mock, RE Weiner - International Journal of Radiation Applications and …, 1988 - Elsevier
A simplified method is described for labeling m-Iodobenzylguanidine (mIBG) with high-purity
Na 123 I. Using stable stock solutions of mIBG and ammonium sulfate, a dry-block heater at …

[PDF][PDF] Early detection of bleomycin-induced lung injury in rat using indium-111-labeled antibody directed against intercellular adhesion molecule-1

RE Weiner, DE Sasso, MA Gionfriddo… - Journal of Nuclear …, 1998 - Soc Nuclear Med
111ln* alCAM-1 or1111n-labelednormal mouse IgG (111ln* nmlgG) and were imaged and
killed 24 hr later. Lung injury was induced by an intratracheal injection of bleomycin 4 or 24 …

The molecular weight of bovine lactoferrin

RE Weiner, S Szuchet - Biochimica et Biophysica Acta (BBA)-Protein …, 1975 - Elsevier
THE MOLECULAR WEIGHT OF BOVINE LACTOFERR1N The molecular weight of bovine
lactoferrin in a neutral solvent (eg 0.2 M NaC1, pH Page 1 Bioehimica et Biophysica Acta, 393 …

[PDF][PDF] Role of phosphate-containing compounds in the transfer of indium-111 and gallium-67 from transferrin to ferritin

RE Weiner - Journal of nuclear medicine, 1989 - Soc Nuclear Med
METhODS Indium-I11 or †7Gabindingto HoFE To examinethe influenceof ATP and PP@
on 67Gabinding to HoFF, an aliquot of a stock 10-mM ATP, PP1, or buffer solution was added …