Investigation of high resolution compact gamma camera module based on a continuous scintillation crystal using a novel charge division readout method

QS Dai, CL Zhao, H Zhang, Y Qi - 2010 - ro.uow.edu.au
The objective of this study is to investigate a high performance and lower cost compact gamma
camera module for a multi-head small animal SPECT system. A compact camera module …

Principle and application of sensitivity calibration by single particle for current detector

S Zhaohui, D Qiusheng, W Kuilu, R Xichao - High Power Laser and Particle …, 2005 - osti.gov
A method adopting the charge analog digital conversion technique to calibrate a current
scintillation detector is described. Each pulse charge produced by a single particle is collected …

Implementing analytical geometric and penetration response correction for keel-edge pinhole SPECT image reconstruction

X Zhang, Q Dai, Y Qi - 2008 IEEE Nuclear Science Symposium …, 2008 - ieeexplore.ieee.org
The collimator response compensation is very important in high-resolution pinhole SPECT
imaging for resolution recovery and quantitative imaging. In this study the pinhole collimator …

Implementation of high-resolution pinhole SPECT 3D image reconstruction

QS Dai, Y Qi - 2009 - ro.uow.edu.au
In order to achieve high-resolution pinhole SPECT image reconstruction, a novel lookup
table (LUT) method was implemented in the ordered subsets expectation maximization (OSEM) …

Design and Implementation of Simplified Readout Circuits for Multi anode Position sensitive Photomultiplier Tubes

…, QI Yu-jin, SHI Liang, JIN Qing, DAI Qiu-sheng - 原子核物理评论, 2010 - npr.ac.cn
The multi anode position sensitive photomultiplier tube (PSPMT) has been used for the
development of high resolution γ camera module. This study is aimed to investigate the …

A Method of Improving the Formula of Binding Energyand Its Universal Revised Formula

GL ZHANG, WB JIA, QS DAI, BX YU, TL SU - Chinese Physics C, 2002 - hepnp.ihep.ac.cn
The action among nucleons is simplified as the bond of nuclear force from which the formula
of volume energy and the formula of surface energy are inferred. And the two parameters …

Channel model of pinhole gamma camera

QS Dai - Chinese Science Bulletin, 2011 - Springer
The pinhole gamma camera is the basis of the newly developed method of high-resolution
pinhole single photon emission computed tomography (SPECT). In this paper, a pinhole …

Energy response of a PbWO4 scintillation detector to gamma and neutron radiation

Z Song, K Wang, X Guan, Q Dai - Measurement Science and …, 2005 - iopscience.iop.org
A scintillation detector based on PbWO 4 is used to measure gamma rays in a mixed
neutron/gamma field from a high intensity pulsed reactor. In order to calibrate gamma sensitivities, …

A cost-effective design of compact gamma camera module based on continuous crystal

D Qiusheng, Z Cuilan, Q Yujin - Nuclear Techniques, 2010 - osti.gov
This work is aimed at developing a compact gamma camera module of high spatial resolution,
based on block scintillation crystal coupling with position sensitive photomultiplier (PSPMT…

Optimized design of X-ray spectrum filter for CT

DAI Qiu-sheng, XU Pin, X Xiao-man - CT Theory and Applications, 2011 - cttacn.org.cn
The optimized design of X-ray spectrum filter for computed tomography is studied by Monte
Carlo method in this paper. The generation process of X-ray using electron bombardment …