Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals
…, H Trojan, U Haberkorn, P Schmidlin… - European journal of …, 1997 - Springer
The purpose of this work was to improve of the spatial resolution of a whole-body positron
emission tomography (PET) system for experimental studies of small animals by incorporation …
emission tomography (PET) system for experimental studies of small animals by incorporation …
Quantitative evaluation and imaging of functions using pattern recognition methods
P Schmidlin - Physics in Medicine & Biology, 1979 - iopscience.iop.org
A method for the quantitative evaluation of function curves is described. Factor analysis is
used to extract from a curve a few parameters which will characterise the curve in detail. The …
used to extract from a curve a few parameters which will characterise the curve in detail. The …
Improved iterative image reconstruction using variable projection binning and abbreviated convolution
P Schmidlin - European journal of nuclear medicine, 1994 - Springer
Noise propagation in iterative reconstruction can be reduced by exact data projection. This
can be done by area-weighted projection using the convolution method. Large arrays have to …
can be done by area-weighted projection using the convolution method. Large arrays have to …
Subsets and overrelaxation in iterative image reconstruction
P Schmidlin, ME Bellemann, G Brix - Physics in Medicine & …, 1999 - iopscience.iop.org
A number of iterative image reconstruction algorithms were integrated into one formula
characterizing each algorithm by only two parameters: overrelaxation and number of subsets. …
characterizing each algorithm by only two parameters: overrelaxation and number of subsets. …
Iterative reconstruction of PET images using a high-overrelaxation single-projection algorithm
P Schmidlin, ME Bellemann, G Brix - Physics in Medicine & …, 1997 - iopscience.iop.org
An iterative image reconstruction procedure is described which is able to calculate high-precision
images within eight iterative steps. High initial overrelaxation parameters are used …
images within eight iterative steps. High initial overrelaxation parameters are used …
[PDF][PDF] The exercise renogram. A new approach documents renal involvement in systemic hypertension
JH Clorius, P Schmidlin - Journal of Nuclear Medicine, 1983 - Soc Nuclear Med
METHODS We report on 76 patients referred for hippurate scin tigraphy because of
hypertension. For inclusion in the study, patients had to have a minimum systolic blood
hypertension. For inclusion in the study, patients had to have a minimum systolic blood
Predictive value of exercise renography for presurgical evaluation of nephrogenic hypertension.
…, J Allenberg, T Hupp, LG Strauss, P Schmidlin… - …, 1987 - Am Heart Assoc
Functional omicron-iodohippurate scintigrams were obtained in 18 hypertensive patients.
Each patient was examined in the prone position and during exercise. An exercise-induced …
Each patient was examined in the prone position and during exercise. An exercise-induced …
Clinical evaluation of patients with hypertension and exercise-induced renal dysfunction.
JH Clorius, J Mann, P Schmidlin, LG Strauss, T Saur… - …, 1987 - Am Heart Assoc
An exercise-mediated renal omicron-iodohippurate transport abnormality was recently
identified in patients with hypertension. The disturbance was not observed in normotensive …
identified in patients with hypertension. The disturbance was not observed in normotensive …
[PDF][PDF] The exercise renogram and its interpretation
JH Clorius, T Hupp, I Zuna, P Schmidlin… - Journal of Nuclear …, 1997 - Soc Nuclear Med
MATERIALS AND METHODS Seventy hypertensive patients with renovascular disease had
resting and exercise renography. All patients had renovascular disease, demonstrated by …
resting and exercise renography. All patients had renovascular disease, demonstrated by …
[PDF][PDF] Renovascular hypertension: a perfusion disturbance that escaped recognition
…, T Hupp, A Mandelbaum, P Schmidlin… - Journal of Nuclear …, 1993 - Soc Nuclear Med
METHOD Twenty-three patients, referred for evaluation of renovascular hypertension, and 7
normotensive controls were studied. The control group included only healthy normotensive …
normotensive controls were studied. The control group included only healthy normotensive …